PIN
Name
Description
6
CAN_L_0
Connection of additional CAN clients to port 0 or termination
of the CAN interface port 0 (CAN terminating resistor)
7
CAN_H_1
CAN-High Port 1 (CAN 2.0)
8
CAN_L_1
CAN-Low Port 1 (CAN 2.0)
9
EN
Release of the inverter modules – modulation permissible
(KL15 – Switched plus from ignition starter switch)
10
reserved
KEB Service interface
11
reserved
12
reserved
13
reserved
14
reserved
15
reserved
16
HVIL_IN
Input High Voltage Interlock
„4.3.1.1 High Voltage Interlock Loop (HVIL) - Exemplary
17
HVIL_OUT
Output High Voltage Interlock
„4.3.1.1 High Voltage Interlock Loop (HVIL) - Exemplary
18
CAN_H_0_R
Connection bridge for termination of the CAN interface port 0
19
CAN_H_1_R
Connection bridge for termination of the CAN interface port 1
20
CAN_L_1
Connection bridge for termination of the CAN interface port 1
21
reserved
KEB Service interface
22
reserved
23
reserved
Figure 33:
Assignment of the terminal block X1A
„4.4.2 Connection plug for X1A“.
73
CONNECTION Of THE CONTROL