Encoder Interface UVW / TTL Output
GB-6
2.
Mechanical installation
All kind of works on the inverter may be carried out by authorized personnel in accordance
with the EMC and safety rules only.
• Switch inverter de-energized and await capacitor discharge time
• Pull off operator
• Remove plastic cover
• Remove fixing bolt
• Fix interface board beginning from the socket connector straightly
• Screw in fixing bolt
• Attach plastic cover
.
Description of the Interface
.1
Voltage supply
Figure .1 Voltage supply of control and encoder interfaces
U
int
24 VDC
Internal voltage supply of COMBIVERT.
X2A
X3A
X3B
5,2V
24V
5V
24V
5V
U
int
5EXT
I
int
140 mA
U
ext
Control terminal strip (X2A) of the COMBIVERT with
external voltage supply 24…0 DCV.
24 V Voltage output of encoder interfaces XA and XB for
encoder supply.
I
24V
Current I
int
reduces itself by draw current to the 5 V output
in accordance with the following formula:
5,2 V x I
5V
I
24V
= I
int
- –––––––––
U
int
5 V Voltage output for encoder supply. 5,2 V are obtained
from the 24 V voltage.
I
5V
400 mA Total for both encoder interfaces
.2
Channel 1
XA
Socket SUB-D15
Interface type
UVW
Input signals
5 V TTL according to RS-422 / -485
Inputs / incremental tracks
A, B and N with the respective inverted signals
Absolute track
Block commutation tracks U, V, W
Limiting frequency
200 kHz
Increments per revolution
1…4096 inc (recommendation 2500 inc for speed upto
4500 rpm)