KC-P30 x-series
Web interface
Configuration manual V4.14
24
© KEBA
If a client charging station loses the connection to the master, or if an error
occurs at the master, a specification can be made for the maximum charging
current at which charging is to be continued. If "0" is entered, the charging
process is terminated in the event of an error and the charging station is put
into "out of operation" mode.
4.1.5
System
The area offers the following options:
●
Software Update
●
Mobile Communications Info
●
Logging
●
DSW Settings
●
Factory Data Reset
●
Signed measurement data export
●
Signed log data export
●
Restart System
●
Certificates
Software-Update
The currently installed software versions are displayed. A software update
can also be performed here.
Mobile Communications Info
Information about the mobile communications connection is displayed and
the connection to the selected mobile communications network can be
tested.
Logging
The event log can be downloaded here.
DSW Settings
The DIP switch settings of each charging station in the charging network can
be displayed here.
Factory Data Reset
The "Reset" button resets the configuration of the charging station to the fac-
tory settings and all stored data (charging sessions, taught-in RFID cards,
web interface password, etc.) is deleted.