KC-P30 x-series
Web interface
Configuration manual V4.14
27
© KEBA
OCPP certificates
Certificate
Purpose
Charge point certificate
Encrypted connection to the OCPP server
Central system root certificate
Certificate for logging in to the charging sta-
tion at the OCPP backend (OCPP 1.6 JSON
Security)
OCPP server certificate
Encrypted connection to the charging station
Manufacturer root certificate
Check of the signature for firmware updates
(OCPP 1.6 JSON Security)
External TCP Meter
Here, a setting is configured for whether the measured values are read out
from external meters in order to dynamically adapt the charging current. All
necessary configurations for the external meter can be specified in this area.
Display Text
Here, you can make settings for the text that is shown on the display of the
charging station describing various processes of the charging station. The
language of the text can be changed, the display duration can be configured
and the display text itself can be changed.
The text display is limited to 20 characters, and no umlauts or special char-
acters can be used.
The abbreviations "Wh" and "kWh" must not be used in the display texts as
they may be misleading to the user. These abbreviations are reserved for in-
dicating transmitted energy. If either "Wh" or "kWh" are entered as display
text anyway, this text is ignored and not shown on the display.
4.2
User menu
The user menu contains important information and settings for the user. It is
divided into the following areas:
●
Help
●
Licenses
●
User settings
●
Logout
User settings
In this area, changes to the following user settings can be made:
Username and password
The web interface username and the corresponding password can be
changed here. The following rules apply for assigning the password:
●
At least 10 characters long