UDP commands 

 

7 / 12 

2.4 

UDP command “i” 

 

UDP command: 

i

 

 

Reply: 

 

"Firmware":"KEBA P20 v 2.5a3 (160613-061001):29309:143.0" 

 

 

Description: 
 

 

Returns the product family and the firmware version of the charging station. 

 

Serves to a possible inventory of the network by means of a broadcast command 
with a subsequent report for detailed queries. 

 

 
 

2.5 

UDP command “failsafe” 

 

UDP command: 

failsafe [Timeout] [curr] [save]

 

 

Reply: 

 

"TCH-OK :done" 

 

 

Description: 
 

 

[Timeout] 

10...600 = Within this time, a command "ena" or "curr" must be 

 

 

received, in order not to activate the failsafe mode. 

 

 

0 = Disables the failsafe mode. 

 

[curr] 

 

0 = Disables the charging process when triggering the failsafe 

 

 

function, similar to command "ena 0". 

 

 

 

6000...63000 = Reduces the maximum allowed charging current 

 

 

to this value (in milliampere), when triggering the failsafe function. 

 

[save]    

0 = Activates the failsafe function only temporary until the next 

 

 

startup of the device. 

 

 

 

1 = Saves the settings into the EEPROM in order to activate the 

 

 

failsafe function automatically, after restarting the device. 

 
By default, this feature is disabled and must be enabled once or after each restart. 
This function is used to limit a network charging station with a lost communication 
(network error, server failure, ...) to a defined state. This can be necessary in con-
junction with a peak load limitation, in order not to overload the main fuses. 
An activated failsafe function is indicated by the charging station. In this case the 
LED segments do not longer illuminate the full width, but only indicates the current 
state with the middle two LED segments. 
A triggered failsafe function can be also recognized over UDP: in the report 2 the 
"

Enable sys

" value goes to 0, and the charge current setting "

Max curr

" goes to 

the default value of "

Curr FS

". 

After the failsafe function has been activated due to a timeout, you must set the val-
ues of current and the load enable again using the associated commands "curr" and 
"ena". 

 

 

Summary of Contents for KeContact P20

Page 1: ...KeContact P20 Charging station UDP Programmers Guide V 3 00 Original manual...

Page 2: ...meanings Notice Notes on use of equipment and useful practical tips are identified by Notice Notices do not con tain any information that draws attention to potentially dangerous or harmful functions...

Page 3: ...ommands 5 2 1 General information 5 2 2 Supported UDP commands 5 2 3 UDP Broadcast Messages 6 2 4 UDP command i 7 2 5 UDP command failsafe 7 2 6 UDP command report 8 2 7 UDP command ena 10 2 8 UDP com...

Page 4: ...realize e g a reduction of your energy con sumption in conjunction with a photovoltaic system and your charging station Schematic overview example 1 1 Requirements The following requirements have to...

Page 5: ...nt to the charging station as simple text commands without end characters such as CR or LF The answers come as data packages with up to 512 bytes and are formatted in JSON standard each data line with...

Page 6: ...RFID not enabled 2 ready for charging waiting for EV charging request S2 3 charging 4 error 5 authorization rejected Plug Current condition of the loading connection 0 unplugged 1 plugged on charging...

Page 7: ...l the next startup of the device 1 Saves the settings into the EEPROM in order to activate the failsafe function automatically after restarting the device By default this feature is disabled and must...

Page 8: ...put 0 Input 0 Serial 15017355 Sec 4294967296 Description ID ID of the retrieved report State Current state of the charging station 0 starting 1 not ready for charging e g unplugged X1 or ena not enabl...

Page 9: ...energy limit Output State of the output X2 Input State of the potential free Enable input X1 When using the input please pay attention to the information in the installation manual Serial Serial numbe...

Page 10: ...adcast message ATTENTION Some electric vehicles EVs do not yet meet the standard requirements and an ena 0 can lead to an error in the charging station 2 8 UDP command curr UDP command curr n Reply TC...

Page 11: ...eiving of the command and not the cor rectness of the value Values between 2 and 9 are not answered reserved functions Invalid values e g letters are leading to a deactivation of the relay The correct...

Page 12: ......

Reviews: