UDP commands 

 

9 / 12 

"Enable user"  = Enable condition via UDP. 

 

"Max curr" 

= Current preset value via Control pilot in milliampere. 

 

"Max curr %" 

= Current preset value via Control pilot in 0,1% of the PWM value 

 

"Curr HW" 

= Highest possible charging current of the charging connection. 

 

 

Contains device maximum, DIP-switch setting, cable coding and 

 

 

temperature reduction. 

 

"Curr user" 

= Current preset value of the user via UDP; Default = 63000mA. 

 

"Curr FS" 

= Current preset value for the Failsafe function. 

 

"Tmo FS" 

= Communication timeout before triggering the Failsafe function. 

 

"Curr timer" 

= Shows the current preset value of currtime. 

 

"Tmo CT" 

= Shows the remaining time until the current value is accepted.

 

 

"Setenergy” 

= Shows the set energy limit. 

 

"Output" 

= State of the output X2. 

 

"Input"   

= State of the potential free Enable input X1. 

 

 

When using the input, please pay attention to the information  

 

 

in the installation manual. 

 

"Serial"  

= Serial number 

 

"Sec"   

= Current system clock since restart of the charging station. 

 
 

UDP command: 

report 3

 

 

Reply: 

 


"ID": "3", 
"U1": 230, 
"U2": 230, 
"U3": 230, 
"I1": 99999, 
"I2": 99999, 
"I3": 99999, 
"P": 99999999, 
"PF": 1000, 
"E pres": 999999, 
"E total": 9999999999, 
"Serial": "15017355", 
"Sec": 4294967296, 

 

 

Description: 

 

"ID" 

 

= ID of the retrieved report. 

 

"U1"|"U2"|"U3"| = Current voltage in V. 

 

"I1"|"I2"|"I3"| 

= Current current value of the 3 phases in mA. 

 

"P"  

 

= Current power in mW (Real Power). 

 

"PF"  

 

= Power factor in 0,1% (cosphi) 

 

"E pres"  

= Power consumption of the current loading session in 0,1Wh; 

 

 

   Reset with new loading session (state = 2). 

 

"total"   

= Total power consumption (persistent) without current loading 

 

 

   session 0,1Wh; Is summed up after each completed charging  

 

 

   session (state = 0). 

 

"Serial"  

= Serial number 

 

Summary of Contents for KeContact P20

Page 1: ...KeContact P20 Charging station UDP Programmers Guide V 3 00 Original manual...

Page 2: ...meanings Notice Notes on use of equipment and useful practical tips are identified by Notice Notices do not con tain any information that draws attention to potentially dangerous or harmful functions...

Page 3: ...ommands 5 2 1 General information 5 2 2 Supported UDP commands 5 2 3 UDP Broadcast Messages 6 2 4 UDP command i 7 2 5 UDP command failsafe 7 2 6 UDP command report 8 2 7 UDP command ena 10 2 8 UDP com...

Page 4: ...realize e g a reduction of your energy con sumption in conjunction with a photovoltaic system and your charging station Schematic overview example 1 1 Requirements The following requirements have to...

Page 5: ...nt to the charging station as simple text commands without end characters such as CR or LF The answers come as data packages with up to 512 bytes and are formatted in JSON standard each data line with...

Page 6: ...RFID not enabled 2 ready for charging waiting for EV charging request S2 3 charging 4 error 5 authorization rejected Plug Current condition of the loading connection 0 unplugged 1 plugged on charging...

Page 7: ...l the next startup of the device 1 Saves the settings into the EEPROM in order to activate the failsafe function automatically after restarting the device By default this feature is disabled and must...

Page 8: ...put 0 Input 0 Serial 15017355 Sec 4294967296 Description ID ID of the retrieved report State Current state of the charging station 0 starting 1 not ready for charging e g unplugged X1 or ena not enabl...

Page 9: ...energy limit Output State of the output X2 Input State of the potential free Enable input X1 When using the input please pay attention to the information in the installation manual Serial Serial numbe...

Page 10: ...adcast message ATTENTION Some electric vehicles EVs do not yet meet the standard requirements and an ena 0 can lead to an error in the charging station 2 8 UDP command curr UDP command curr n Reply TC...

Page 11: ...eiving of the command and not the cor rectness of the value Values between 2 and 9 are not answered reserved functions Invalid values e g letters are leading to a deactivation of the relay The correct...

Page 12: ......

Reviews: