KeContact R10 CM
18
Installation Manual V 1.01
(translated)
9. Technical data
9.1
In general
Max. actuation cycles cable pullout:
In accord to the Rolling test
“See Annex 001 EU Declaration of Conformity”
Protection class:
IP44
Connection cross section:
Minimum cross section (depending on the
cable and the line length):
3 x 2.5 + 0.5 mm²
(16A nominal current)
5 x 2.5 + 0.5 mm²
(16A nominal current)
3 x 6.0 + 0.5 mm²
(32A nominal current)
Rated current
16A - 32A
3 phase (only 16A)
Mains voltage (Europe)
230/380V
Main frequency
50/60 Hz
9.2
Environmental conditions
Operating temperature:
-25 °C to +45 °C
(Without direct exposure to sunlight)
Storage temperature:
-25 °C to +80 °C
Relative air humidi
(non-condensing)
:
5 % to 95 %
(not condensing)
Protection class
IP44
Altitude
Max. 2,400 m sea level
Shock resistance:
According to IEC 61316:2021
Information
The environmental conditions for the KeContact R10 must also be
fulfilled during transport.
Technical data