4
3. Installation
3.1. Power supply of the base station
First of all, the base station must be supplied with voltage. To do this, pin 10 of terminal strip S1 must
be supplied with GND and pin 11 of terminal strip S1 with 24V.
Illustration: Picture of the base station with terminal strip S1 (Pin 10 and 11)
As soon as the base station is powered, the PWR led on the base station lights up and the base
station goes into bridged emergency stop status, the bar turns white.
Illustration: PWR Led indicates power supply to the base station
3.2. Power supply of the handheld terminal
Before starting the handheld terminal for the first time, the battery must be installed in the handheld
terminal. To do this, open the cover of the battery compartment
Illustration: Rear side of the handheld terminal with marked cover of the battery compartment