3.4 Installation of the devices for wall mounting
Step
Action
Comment
1.
Arrange the devices on the backing plate as per
Please also provide enough space to the left of the
ServoOne CM-A or ServoOne CM-D (BG3) for the
ServoOne CM-L, the MotionOne CM controller and the
ServoOne SO CM-S switched-mode power supply .
Align all devices in a line along the top edge of the
devices.
It is imperative you observe the information on the butt
mounting of the devices.
This action is necessary to be able to couple
the DC link and the 24 V DC using the pre-
assembled busbars.
2.
Mark out the position of the tapped holes on the
backing plate.
Drill holes in the backing plate and cut a thread for
each fixing screw in the backing plate.
Pay attention to the bending radius of the
connection cables!
For hole spacing and dimensional drawings see
Table 3.1 and Figure 3.4.
3.
Mount ServoOne CM-A or ServoOne CM-D (BG3)
and the ServoOne CM-L (BG1) vertical and with the
ServoOne CM axis controller (BG3) butt-mounted on
the backing plate.
The contact surface must be bare metal and
conductive.
The ServoOne CM-L, (BG1) must be mounted
directly to the left beside the ServoOne CM-A or
ServoOne CM-D (BG3).
Always mount the
ServoOne CM-C capacitance module directly
to the right beside the ServoOne CM-A or
ServoOne CM-D (BG3).
Always mount the
ServoOne SO CM-S switched-mode power supply
directly to the left beside the ServoOne CM-L.
You will find the next steps for the electrical installation in chapter “4 Electrical installation”.
3.4.1
Dimensions, wall mounting model (housing with heat sink)
ServoOne CM-L
BG1
ServoOne CM-A,
BG3
ServoOne CM-D
BG3 *)
Type
SO CM-L.0000 **)
SO CM-A.00L2 **)
SO CM-A.00L4 **)
SO CM-D.00L2
Weight
2.5 kg
10 kg
10 kg
B (width)
54.5
164
164
H (height)
310
430
430
T (total depth)
241
251
251
T1
221
222
222
H1
299
378
378
H2
6
H3
-
390
A
27
A1
110
A2
55
C
4.8
D
-
80
Side clearance
Direct butt mounting
Screws
2 x M4
5 x M4
All dimensions in mm.
*) In preparation. **) Field test approval
Table 3.1
Dimensions for wall mounting
Note:
The ServoOne CM-L must always be fitted directly to the left beside the
ServoOne CM-A or ServoOne CM-D and this must always be mounted to the
left of the axis controllers. The highest power axis controller should be close
to the supply unit. For double-axis controllers the total power counts. The