36
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
4.6.6
ServoOne CM-L: Specification of the LINE IN connection
The mains voltage (L1, L2, L3) for power connection is connected to the LINE IN
connector.
Des.
Term.
Specification
Connection
LINE IN
L1
x
AC mains connection pre-charging
x
3 x 230...480 V AC
x
Connection cross-section: maximum 6 mm
2
L2
L3
x
Connection of the cable shield to the shield
connection rail.
Table 4.8
Specification, AC mains connection ServoOne CM-L charging module LINE IN
Note:
The local regulations on cable protection are to be followed!
4.6.7
ServoOne CM-A: specification, LINE FILTER, SYNC and
LC (Temp) connections
The mains voltage (U, V, W) for power connection is connected to the connector
LINE FILTER. +ZK is connected to connZK on the LC filter. The mains
voltage (L1, L2, L3) for the synchronisation is connected to the connector SYNC. The
temperature sensor for the LC filter is connected to the terminal "LC (Temp)".
SO CM-A.00L2.x
Des.
Term.
Specification
Connection
LINE FILTER
U
x
AC mains connection
x
3 x 230...480 V AC
x
Connection cross-section:
maximum . . . 16 mm
2
LC (T
emp)
V
W
x
Cable shield connection
LC (Temp)
x
Connection for LC filter temperature monitoring
x
Cross-section: 0.14 - 1.5 mm
2
(AWG 24-16)
SYNC
L1
x
AC mains connection mains synchronisation
x
3 x 230-480 V AC
x
Connection cross-section:
maximum 2.5 mm
2
L2
L3
+ ZK -
x
ConnZK for LC filter
x
Connection cross-section: maximum 16 mm
2
Table 4.9
Specification, AC mains connection ServoOne CM-A SO CM-A.00L2.x