16
Mechanical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Mechanical installation
Note:
You will find rules for the arrangement of the various components of the
ServoOne CM system in the <SOCM Manual>.
1
2
3
4
5
6
7
(1) MotionOne CM controller
(2) ServoOne SO CM-S switched-mode power supply
(optional)
(3) ServoOne CM-L charging module
(4) ServoOne CM-A active supply unit
(5) ServoOne CM-C capacitance module (optional)
(6) ServoOne CM axis controller BG3
(7) Other ServoOne CM axis controller BG3
or
ServoOne SO CM-E expansion module (is required if
coupling with ServoOne CM (BG1/BG2) is planned.
Figure 3.1
Butt mounting sequence example configuration
WARNING!
Risk of injury due to hot surfaces on the device (heat sink)!
Carelessness may result in serious burns or damage.
x
The device heats up very significantly during operation and can reach temperatures of up
to 100 °C. If touched there is a risk of burns to the skin. For this reason provide protection
against touching.
x
Please maintain an adequate distance from neighbouring assemblies, particularly above the
heat sink.
The ServoOne SO CM-S switched-mode power supply must always be mounted on the
left of the ServoOne CM-L charging module.
3.2 Mounting clearances
CAUTION!
Damage to the device due to incorrect installation conditions!
The device may suffer irreparable damage if the conditions are not met.
x
The minimum clearances stated in the figure below apply to all devices
(MotionOne CM, ServoOne CM-P BG3+4, ServoOne CM-A active supply unit,
ServoOne CM-D active supply unit, ServoOne CM-L charging module and
ServoOne CM BG3+4).
x
The clearance above the devices is important to prevent the build-up of heat. The clearance
underneath and at the front is necessary to permit correct cable laying.