40
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
X2
24 V DC Netzteil
(Power Supply)
1.
2.
3
2
4
Key:
(1) 24 V DC power supply unit (not included in the scope of supply) (2) MotionOne CM
(3) ServoOne CM-L charging module
(4) ServoOne CM-A or ServoOne CM-D
Figure 4.15
Connection of an external switched-mode power supply to 24 V DC input X2
ServoOne CM-L charging module
Specification, 24 V DC (X2)
Des.
Term.
Specification
Connection
X2
24 V DC
+24 V
x
24 V DC ± 10 %
The sum of the power required
via the busbars must not
exceed 840 W.
x
I
max
connector = 35 A
x
Connection cross-section:
maximum 6 mm
2
.
+24 V
GND
X2
GND
For layout see Figure 4.14
Table 4.13
Specification, 24 V DC input X2 ServoOne CM-L charging module