42
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
4.9.2
Busbars, 24 V control supply from external switched-
mode power supply
1.
2.
3.
4.
5.
6.
24 V DC Netzteil
(Power Supply)
(1) External switched-mode power supply (2) MotionOne CM controller
(3) ServoOne CM-L charging module
(4) ServoOne CM-A or ServoOne CM-D
(5) ServoOne CM-C capacitance module (6) ServoOne CM axis controller
Note:
The 24 V busbar fittings are to be tightened to a tightening torque of 2.1 Nm.
Figure 4.18
Busbars, 24 V control supply from external switched-mode power supply on
24 V DC input X2
CAUTION!
Damage to the drive system due to incorrect wiring!
Carelessness may result in damage to the device.
x
Use the connection elements supplied (busbars) for the electrical coupling of the devices.
x
Make sure that all connections have good contact and are sufficiently secure that they
cannot come loose. Pay attention to the tightening torques for the fittings.
Note:
On the usage of other connection elements (busbars),
KEBA Industrial Automation Germany GmbH does provide any guarantee for
stable, reliable operation.
4.9.1
Busbars, 24 V control supply with SO CM-S
2.
3.
4.
5.
6.
1.
(1) MotionOne CM controller
(2) ServoOne SO CM-S switched-mode power supply
(3) ServoOne CM-L charging module
(4) ServoOne CM-A or ServoOne CM-D
(5) ServoOne CM-C capacitance module (6) ServoOne CM axis controller
Note:
The 24 V busbar fittings are to be tightened to a tightening torque of 2.1 Nm.
Figure 4.17