52
Electrical installation
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Electrical installation
Note:
You will find the specification for the inputs SDIxx and further details on the
SD0 function in connection with the bank of DIL switches S-ADR in the
document "Model Description SD0" ID no.: 1400.402B.x-xx.
Specification for the terminals
The terminal X11 is realised using a 2-layer 2 x 3 pole plug-in terminal with 3.5 mm spacing from Phoenix Contact.
-
− Type: MCDN 1.5/3-G1-3.5
4.13 Motor connection with SO CM-D (in
preparation)
The ServoOne CM-D active supply unit permits the connection of a motor.
NOTE
You will find information on the connection of a motor in the Operation Manual
Axis Controller SO CM BG3+4 (ID no.: 1800.200B.x).
4.14 Encoder connections SO CM-D (in
preparation)
NOTE
You will find information on the connection of the encoders to X7 and X8 in the
Operation Manual Axis Controller SO CM BG3+4 (ID no.: 1800.200B.x).
4.12.4 Specification, X11 Safe-DI
ServoOne CM-A
Switch on supply unit.
The pre-charging of the DC link is started by activating the inputs SDI00 and SDI01
(ENPO CH1 and ENPO CH2). Once pre-charging is complete, the mains contactor is
closed and the supply unit switches over to closed-loop operation.
Figure
X11/Safe-DI
Type
Function
SDIO0
SDIO1
GND
X11 / Safe-DI
n.c.
n.c.
n.c
SDI00
Digital input
ENPO CH1
GND
Reference ground
GND
SDIO1
Digital input
ENPO CH2
Table 4.22
Allocation of the control inputs X11 Safe-DI for ServoOne CM-A
ServoOne CM-D (in preparation)
Switch on supply unit.
The pre-charging of the DC link is started by activating the inputs SDI02 and SDI03
(ENPO CH1 and ENPO CH2). Once pre-charging is complete, the mains contactor is
closed and the supply unit switches over to closed-loop operation.
Figure
X11/Safe-DI
Type
Function
SDIO0
SDIO1
GND
X11 / Safe-DI
SDI02
SDI03
GND
SDI00
Safe digital input
STO 1 CH1
GND
Reference ground
GND
SDIO1
Safe digital input
STO 1 CH2
SDI02
Digital input
ENPO CH1
GND
Reference ground
GND
SDIO3
Digital input
ENPO CH2
Table 4.23