56
Diagnostics
Operation Manual ServoOne CM-L and ServoOne CM-A
ID no.: 1800.208B.1-00 Date: 03/2020
Diagnostics
LED
Status of the active supply unit
Supply
yellow
ERR
red
RUN
green
Supply LED yellow
Status:
on =
(Reset/Starting)
1) Yellow Supply LED
Status:
flickering =
Interface X5.1 will be switched over after next power on
flashing =
Interface is working in Ethernet mode, RUN LED on X5.1 also flickers
off =
Interface is working in EtherCAT mode,
= LED illuminated
= LED off
= LED flashing
Table 5.2 Status LEDs,
ServoOne CM-A active supply unit
5.1.2
ServoOne CM-A active supply unit
Supply
ERR
RUN
Supply LED
Yellow
ERR LED
Red
Error indication using flashing code
RUN LED
Green
Ready
Figure 5.2
Status LEDs, ServoOne CM-A active supply unit
The yellow LED only has a defined function during a software update.
LED
Status of the active supply unit
Supply
yellow
ERR
red
RUN
green
Reset / starting or loading firmware update
-
-
-
Self-initialisation on device startup (Initialisation)
-
1 x
Not ready to switch on
-
2 x
Switch on disabled
-
3 x
Ready to switch on
-
4 x
Switched on
-
Operation enabled
-
Error code
7 x
Fault reaction active
Error code
8 x
Fault
1)
-
-
PtP Ethernet connection in the service and diagnostics mode via the
EtherCAT interface
Table 5.2 Status LEDs,
ServoOne CM-A active supply unit