Flashing code
The Axis 1 LED (yellow) only has a defined function during a software update.
AXIS1
LED
State of the axis
Axis 1
yellow
ERR
red
RUN
green
long (0.8 s) long (0.8 s)
short (0.4
s)
-
Reset / starting
or loading firmware update
-
-
-
-
Self-initialisation on device startup (Initial-
isation)
-
1 x
1 x
Not ready to switch on
-
2 x
2 x
Switch on disabled
-
3 x
3 x
Axis ready to switch on
-
4 x
4 x
Axis switched on
-
5 x
Operation enabled
-
6 x
6 x
Quick stop
-
Error code
7 x
7 x
Fault reaction active
Error code
8 x
8 x
Fault
1)
-
-
-
PtP Ethernet connection in the service and
diagnostics mode via the EtherCAT interface
Green LED long = Motor in the normal mode
Green LED short = Motor in the simulation mode
Yellow Axis 1 LED
Status:
on =
(Reset/Starting)
1) Yellow Axis 1 LED
Status:
flickering =
Interface X5.1 will be switched over after next power on
flashing =
Interface is working in Ethernet mode, RUN LED on X5.1 also flickers
off =
Interface is working in EtherCAT mode,
= LED illuminated
= LED off
= LED flashing
Table 5.3 Status LEDs, ServoOne CM-D active supply unit
5.1.3
ServoOne CM-D active supply unit
Axis 1
ERR
RUN
Supply
ERR
RUN
Axis 1
Axis 1 LED
Yellow
ERR LED
Red
Error indication using flashing code
Voltage LED
Green
Ready/power stage active
Supply
Supply LED
Yellow
ERR LED
Red
Error indication using flashing code
RUN LED
Green
In operation
Figure 5.3
Status LEDs, ServoOne CM-D active supply unit