A.2 Technical data,
ServoOne CM-A active supply unit
Device
Unit
SO CM-A.00L2 *)
SO CM-A.00L4 **)
Input, mains side
Nominal mains voltage U
N
. 3 times
V AC
230
400
480
230
400
480
Tolerance on the supply voltage
± 10 % of U
N
Continuous current, typical
A
AC eff
42
42
36
79
79
67
Peak current typical
A
AC eff
84
84
72
158
158
134
Continuous power, typical
kVA
17
31
31
33
58
58
Power dissipation, typical
Values not yet available at the time of going to press.
Asymmetry of the
mains voltage
%
±3 % max.
Frequency
Hz
50 - 60 Hz ± 10 %
Maximum cable cross-section on
LINE FILTER
mm
2
16
35
Measurement of the mains voltage
The mains voltage (L1, L2, L3) is measured on the connection "SYNC".
Current consumption
A
< 0.5
DC link output
DC link voltage
V DC
380 - 750
600 - 750
380 -750
600 - 750
Continuous current
A DC
50
50
40
91
91
73
Peak current 2 x I
N
for 10 s
A DC
100
100
80
182
182
146
Continuous power P
N
kW
17
30
31
55
Peak power 2 x P
N
for 10 s
kW
34
60
62
110
DC link capacitance only
ServoOne CM-A
µF
2350
*) In preparation; **) Field test approval
Table A.3
Technical data, ServoOne CM-A
A.3 Ambient conditions
Ambient conditions
ServoOne CM-L and ServoOne CM-A
Protection
Device: IP20 - exception terminals (IP00)
Accident prevention regulations
As per the local regulations (in Germany e.g. DGUV V3)
Installation altitude
Up to 1000 m above MSL, higher with power reduction
(1 % per 100 m, max. 3000 m above sea level)
Pollution degree
2 (according to EN 60664-1)
Type of mounting
Built-in unit, only for vertical mounting in a switch cabinet with at least IP4x
protection, on using STO safety function at least IP54
Table A.4
Ambient conditions ServoOne CM-L and ServoOne CM-A
Climatic conditions
ServoOne CM-L and ServoOne CM-A
In transit
As per EN 61800-2, IEC 60721-3-2 class 2K3
1)
Temperature
-25 °C to +70 °C
Relative atmospheric humidity
95 % at max. +40 °C
As per EN 61800-2, IEC 60721-3-1 classes 1K3 and 1K4
2)
In storage
Temperature
-25 °C to +55 °C
Relative atmospheric humidity
5 to 95 %
As per EN 61800-2, IEC 60721-3-3 class 3K3
3)
In operation
Temperature
Air cooling
5 °C to +40 °C (up to +55 °C with power reduction)
Relative atmospheric humidity
5 to 85 % without condensation
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70 °C for example, that the relative atmospheric humidity may
only be max. 40 %.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative atmospheric humidity
stipulated in the table must not occur simultaneously.
3) The absolute humidity is limited to max. 25 g/m³. That means that the maximum values for temperature and relative atmos-
pheric humidity stipulated in the table must not occur simultaneously.
Table A.5
Climatic conditions, ServoOne CM-L and ServoOne CM-A