11.6.8 Error 7: Device heatsink temperature error
11.6.8.1 Error 7-1 (emergency code 4210h)
Cause: Heat sink temperature too high
Suggested steps:
reduce the load and check the conditions of the drive
An overcurrent was
detected.
l
Please check current control settings and step
response.
l
Check the motor's saturation settings
(parameter MOT_LSigDiff). If the error
occurred in high-current range, lower
saturation values manually.
l
If possible, reduce the needed current,
especially in low-frequency range.
l
If possible, lower the switching frequency or
enable automatic frequency selection.
l
Check if the encoder offset is set properly.
l
Consider using an axis module with higher
current rating.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo controller.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
355
11 Alarms & warnings
11.6.9 Error 8: Device inside temperature error
11.6.9.1 Error 8-1 (emergency code 4210h)
Cause: Interior temperature monitor
Suggested steps:
check the conditions of the drive
An overcurrent was
detected.
l
Please check current control settings and step
response.
l
Check the motor's saturation settings
(parameter MOT_LSigDiff). If the error
occurred in high-current range, lower
saturation values manually.
l
If possible, reduce the needed current,
especially in low-frequency range.
l
If possible, lower the switching frequency or
enable automatic frequency selection.
l
Check if the encoder offset is set properly.
l
Consider using an axis module with higher
current rating.
This is possibly a hardware
issue
If other measures fail to solve the problem, please
replace the servo controller.