11.6.13.7 Error 12-7 (emergency code 8130h)
Cause: CAN option: Sync / RxPDO timeout error
Suggested steps:
The device was probably
disconnected from the
master controller, or the
master is overloaded.
l
Please check the bus system connection. Try
to replace the cables.
l
Please try to reduce computational load on the
master.
l
Try to increase the master cycle time.
This is possibly an EMC
issue. This is very likely if the
problem occurs when
switching on motor control
and/ or when connecting DC
link power supply.
l
Please check the device cabling for proper
connection.
l
Please check device grounding, i. e. the
connection to a metal backplane and cabinet
connection to earth.
l
Check motor grounding and motor cable
length.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
361
11 Alarms & warnings
11.6.13.8 Error 12-8 (emergency code FF00h)
Cause: CAN option: Error while parameter initialisation
Suggested steps:
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
11.6.14 Error 13: SERCOS error
11.6.14.1 Error 13-1 (emergency code FF00h)
Cause: Sercos option: Error while hardware initialisation
Suggested steps:
This is possibly a hardware
issue
If other measures fail to solve the problem, please