11.6.16.15 Error 15-16 (emergency code FF00h)
Cause: Selected switch frequency is not possible
Suggested steps:
Change switch frequency or disable PWM-frequency switching
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
11.6.16.16 Error 15-17 (emergency code FF00h)
Cause: Autotuning mode not supported (in this configuration)
Suggested steps:
Please use other autotuning mode or tune by hand
11.6.16.17 Error 15-18 (emergency code FF00h)
Cause: Error in power fail initialization
Suggested steps:
Check power fail parameters or disable function
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
374
11 Alarms & warnings
11.6.16.18 Error 15-19 (emergency code FF00h)
Cause: Error in camming or electronic gearing initialization
Suggested steps:
Check parameter or IEC configuration
11.6.16.19 Error 15-20 (emergency code FF00h)
Cause: Error in configuration of CAM module
Suggested steps:
Check for even number of configured cam edges. All configured cam edges have to
be in ascending order.
11.6.16.20 Error 15-21 (emergency code FF00h)
Cause: Dataset to be loaded is not valid
Suggested steps:
Check Parameter PRam_PARA_DataSetLdVal
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.