8.3 Basic settings
Image 8.24: “Basic settings” screen
Interpolation
See Section "Interpolation" on page 249.
NOTE
l
The reference filters are initialized only after the control has been
re-enabled or by a device restart.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
244
8 Motion profile
ID
Index Name
Unit Description
144
0
MPRO_DRVCOM_
AUTO_START
DriveCom: Auto start of system
159
0
MPRO_CTRL_SEL
Motion profile selection
165
0
MPRO_REF_SEL
Motion profile selection
166
0
MPRO_REF_JTIME
ms
Motion profile jerk time
167
0
MPRO_REF_OVR
%
Motion profile override factor
223
0
MPRO_REF_Config
Motion profile: Config of specific profiling
behaviour
301
0
CON_REF_Mode
Mode selection of setpoint profiling
306
0
CON_IpRefTS
ms
Sampling time (for interpolation)
335
0
CON_SCON_DirLock
Direction lock for speed reference value
370
0
CON_IP
Interpolation type
755
0
MPRO_FG_
RefPosFilType
Position reference filter type
756
MPRO_FG_
RefPosFilData
Reference position filter data
756
0
RefFil_TimeConst
ms
Position reference filter time constant
(PT1/PT2/AVG)
756
1
RefFil_DampConst
Position reference filter damping constant
2243
0
MPRO_402_
MotionProfType
Profile type
Table 8.17: “Motion profile - Basic settings” parameters
8.3.1 PG mode with speed control
l
Select reference source
l
Motion profile adaptation: scaling, ramps and smoothing time.
l
In reference processing by way of the profile generator the fine interpolator is
always in use.