9.5 Analogue outputs (option only for
ServoOne)
Image 9.14: “Function selection of optional analogue outputs (option)” screen
If your ServoOne features the "C 2AO" technology option, you will have
two analogue outputs available, enabling you to output values from the controller
using analogue signals. The function selector offers nine variables for selection for
each output. These variables can be filtered, scaled, and assigned an offset.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
320
9 Inputs/Outputs settings
9.5.1 Function selectors
ID
Index Name / Setting
Unit Description
129, 130
0
MPRO_OUTPUT_FS_
OEAxx
Function selectors for analogue outputs
OFF (0)
No function
NACT(1)
Actual speed
TACT(2)
Actual torque/force
IRMS(3)
Effective current
PARA (4)
Value of parameter 134[0]
ACTPOS(5)
Position actual value
VDC(6)
DC link voltage
ACTPOS_MODULO(7)
Actual modulo position
ACT_POWER(8)
Power
APP_POWER(9)
Apparent power
Table 9.14: “Analogue outputs” function selectors
NOTE
l
For a full description of the analogue outputs in the
"2AO" communication option (technical data,
connections, configuration), see the "C 2 analogue
outputs Specification" (ID No.: 1108.20B.x).
l
The technology option “C 2AO” is not available for
ServoOne junior.
l
To determine whether your ServoOne comes with the
"C 2AO" technology option, you can check the
electronic rating plate (see Section "Electronic rating plate" on
page 472).