Loading a motor data set
l
Motor data and control settings screen
l
Select data set
l
Enter encoder settings
l
Save data
Commissioning a third-party motor
In the case of third-party motors, basic suitability for operation with Servo controllers
from KEBA must first be verified on the basis of the motor data and the data of any
installed encoder. The values of the parameters for adaptation of the Servo
controller must be determined specifically for each motor by calculation or
identification. The two methods differ in that when the motor data set is calculated,
the impedances must be taken from the data sheet. The impedances are measured
automatically during identification. Each motor can only be operated if its field model
and the control parameters are correctly set.
On transfer of a standard motor data set the motor name, electrical data and motion
mode are loaded. Preset parameters are overwritten. The motor data must then be
saved in the device. The motor parameters specified by the manufacturer ensure
that a motor can be subjected to load according to its operational characteristic,
provided the corresponding power is supplied by the controller.
NOTE
l
Each motor can only be operated if its field model and the control
parameters are correctly set.
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
33
5 Motor
5.2 Synchronous motor
Image 5.2: “Synchronous motor settings” screen
There are two ways to create a motor data set for the rotary synchronous motor.
l
Variant 1: Motor calculation
l
Variant 2: Motor identification (see Section "Motor identification" on page 45)