ID
Index Name
Unit
Description
C
71
6
Temp_Int
deg
C
Absolute temperature of interior
72
ErrorAbsCount
Absolute error counters
72
0
Over voltage
Overvoltage
72
1
Over current
Overcurrent
72
2
Inverter overtemp.
Overheating
72
3
Device overtemp.
Overheating
72
4
I2t power amplifier
I2t power amplifier or chopper absolute
errors
72
5
-
Reserved
72
6
-
Reserved
72
7
-
Reserved
Table 11.3: “Alarms & warnings (Details)” parameters (continue)
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
337
11 Alarms & warnings
11.3 Warning thresholds
l
P 730 - MON_WarningLevel
can be used to define warning thresholds in
order to prevent Servo controller nuisance tripping. Each warning is
assigned on and off thresholds. This enables parameterization of a
hysteresis that meets the requirement of the application. Warnings can also
be programmed onto digital outputs.
ID
Index Name
Unit Description
730
MON_WarningLevel
Warning levels
730
0
UnderVoltage_ON
V
DC link undervoltage
730
1
UnderVoltage_OFF
V
DC link undervoltage
730
2
OverVoltage_ON
V
DC link Overvoltage
730
3
OverVoltage_OFF
V
DC link Overvoltage
730
4
I_ON
A
Motor current
730
5
I_OFF
A
Motor current
730
6
DeviceI2t_ON
%
I²xt device protection
730
7
DeviceI2t_OFF
%
I²xt device protection
730
8
MotorI2t_ON
%
I²xt motor protection
730
9
MotorI2t_OFF
%
I²xt motor protection
730
10
Torque_ON
Nm
Torque limit reached
730
11
Torque_OFF
Nm
Torque limit reached
730
12
Speed_ON
rpm
Speed limit reached
730
13
Speed_OFF
rpm
Speed limit reached
730
14
TC_ON
degC Maximum heat sink temperature reached
730
15
TC_OFF
degC Maximum heat sink temperature reached
730
16
Tint_ON
degC Maximum interior temperature reached
730
17
Tint_OFF
degC Maximum interior temperature reached
730
18
MotorTemp_ON X5
degC Maximum motor temperature reached
(temperature sensor on X5)
730
19
MotorTemp_OFF X5
degC Maximum motor temperature reached
(temperature sensor on X5)
730
20
MotorTemp_ON X6
degC Maximum motor temperature reached
(temperature sensor on X6)
730
21
MotorTemp_OFF X6
degC Maximum motor temperature reached
(temperature sensor on X6)
Table 11.4: “Warning thresholds” parameters