12.4 PROFIBUS / PROFINET
NOTE
l
For a full description of the PROFIBUS and PROFINET fieldbus
options for the ServoOne and ServoOne junior (operation, system
requirements, connection, operating modes, configuration,
commissioning), see the PROFIBUS and PROFINET User manual
(ID No.: 1108.27B.x).
l
PROFIBUS and PROFINET are defined in IEC 61158 and
IEC 61784.
l
For general information on PROFIBUS and PROFINET, please
visit
ID No.: 0842.26B.5-01 Date: 09.2020
ServoOne - Device Help
457
12 Fieldbus
12.5 Synchronization / Configuration
This function is used to synchronize the internal controller clock with an external
sync signal (e.g. from a fieldbus). When applications are experiencing a lot of jitter,
this function makes it possible to eliminate it to the greatest extent possible.
NOTE
l
If you are under the impression that your application requires the
use of this special function, please contact your project engineer
or Helpline (see Section "Support " on page 14).
ID
Index Name
Unit Description
2008
COM_SYNC_CTRL
Set-up of fieldbus synchronization control
2008
0
COM_SYNC_CTRL_Ref
15ns Reference time for incoming sync telegrams
relative to AD start
2008
1
COM_SYNC_CTRL_Wnd 15ns Window for detecting axis synchronization
2008
2
COM_SYNC_CTRL_kp
DC link controller: Gain
2008
3
COM_SYNC_CTRL_ki
ms
integration
2008
4
COM_SYNC_CTRL_max us
Maximum control output value
2008
5
COM_SYNC_CTRL_min
us
min control output
2008
6
COM_SYNC_CTRL_Tfil
ms
synchronization filter time
2008
7
COM_SYNC_CTRL_____
-
155
0
MPRO_DRVCOM_CFG
DriveCom: Device configuration (requires
restart)
2009
0
COM_CFG_File
Generates fieldbus specific config file
Table 12.1: Synchronization / Configuration parameters