25
Picture 4-12 Enter Guard Area
Setting steps:
1) Check
“
Enable
”;
2) Select a number from the dropdown list of
Guard Line
and once only one area is allowed.
After saving it, user can set another and max 4 guard areas can be set;
3)
Target Filter
: to set target area. Click
“
Edit
” and drag the mouse in the scene to draw a
rectangle. Click
“
Stop
” after finishing and drag the slide bar of “Max and Min Target Ratio”
(1% by default). Moving objects exceeding max and less than min will not trigger an
alarm when they enter the guard area(s);
4)
Area Setting
: to set guard area. Click
“Edit” and click mouse to draw a closed area made
up of 3 to 6 points in the scene. Right click or click the starting point or end point to close