PREPARATIONS
1. FLOOR PLATE AND OUTDOOR AIR
CONNECTION
Arrange the floor plate according to the instructions
on page 4 under the heading Floor plate. If you
choose to make your own floor plate, the minimum
dimensions stated in the above-mentioned point must
be followed at all times.
The illustrations to the right show the dimensions of
the ready-made floor plate, which is available as an
accessory.
If a connection to the outdoor air is required, a sheet
metal drum must be installed according to one of the
alternatives illustrated, either below or through the
rear wall.
Please note that
all dimensions are given presum
-
ing the stove is placed at the minimum permitted
distance from flammable structural units.
2. FLUE CONNECTION
There are two alternatives for connecting the flue.
Alternative 1: Rear installation
Alternative 2: Top installation
Height from the floor to the centre of the flue at the
rear:
665
mm
Height from the floor to the height of the connection
top:
820
mm
Outer diam. of the rear/top sleeve connection: ∅125
For so-called top connection of the chimney, this has
to be done after the stove has been installed. We will
return to this at the end of the Installation instructions
on p. 9.
For so-called rear connection of the stove, this has to
be prepared before the stove is put into place. Note
that side routing and long horizontal routing affect the
draught negatively. For satisfactory function with a
chimney pot of 3.5 m, the length of the horizontal flue
may not exceed 0.5 m.
There are many different requirements and variants
for the rear connection of stoves. We have chosen
to show two different examples, A and B, on the next
page.
- 5 -
820
665
Outdoor air
Rear Installation
Outdoor air
Bottom Installation
Floor Plate
Outdoor air Rear Installation
Height 95mm from the floor
Floor plate