PREPARATIONS

1. FLOOR PLATE AND OUTDOOR AIR 
    CONNECTION

Arrange the floor plate according to the instructions 

on page 4 under the heading Floor plate. If you 

choose to make your own floor plate, the minimum 

dimensions stated in the above-mentioned point must 

be followed at all times.

The illustrations to the right show the dimensions of 

the ready-made floor plate, which is available as an 

accessory.

If a connection to the outdoor air is required, a sheet 

metal drum must be installed according to one of the 

alternatives illustrated, either below or through the 

rear wall.

Please note that

 all dimensions are given presum

-

ing the stove is placed at the minimum permitted 

distance from flammable structural units.

2. FLUE CONNECTION

There are two alternatives for connecting the flue.

Alternative 1:  Rear installation

Alternative 2:  Top installation

Height from the floor to the centre of the flue at the 

rear: 

665 

mm

Height from the floor to the height of the connection 

top: 

820

 mm

Outer diam. of the rear/top sleeve connection: ∅125

For so-called top connection of the chimney, this has 

to be done after the stove has been installed. We will 

return to this at the end of the Installation instructions 

on p. 9.

For so-called rear connection of the stove, this has to 

be prepared before the stove is put into place. Note 

that side routing and long horizontal routing affect the 

draught negatively. For satisfactory function with a 

chimney pot of 3.5 m, the length of the horizontal flue 

may not exceed 0.5 m.

There are many different requirements and variants 

for the rear connection of stoves. We have chosen 

to show two different examples, A and B, on the next 

page. 

- 5 -

820

665

Outdoor air

Rear Installation

Outdoor air

Bottom Installation

Floor Plate

Outdoor air Rear Installation

Height 95mm from the floor 

Floor plate

Summary of Contents for K700

Page 1: ...K700 Installation Instructions Care and firing instructions...

Page 2: ...plate Outdoor air supply Flue Chimney connections PREPARATIONS 5 7 Flue connections for rear and top installation Floor plate and outdoor air connection Unpacking Dismantling INSTALLATION INSTRUCTION...

Page 3: ...sional perform the installa tion Our dealers can recommend suitable fitters You can find information about our dealers on www keddy se The Clean Air Act 1993 and Smoke Control Areas Under the Clean Ai...

Page 4: ...an use Keddy s own floor plate or floor glass These are installed after completing the installa tion of the stove OUTDOOR AIR SUPPLY For the combustion of wood air supply air is required The K700 can...

Page 5: ...stallation Alternative 2 Top installation Height from the floor to the centre of the flue at the rear 665 mm Height from the floor to the height of the connection top 820 mm Outer diam of the rear top...

Page 6: ...he connecting pipe passes through a flammable wall The flammable wall therefore must be furnished with a shaft with fire retardant lining Masterboard Minerit or equivalent and be insulated with at lea...

Page 7: ...heck horizontally and vertically with the help of a spirit level is on the hearth s sealing plate Tip The stove is vertical and horizontal when the door stays open at an opening an gle greater than 90...

Page 8: ...s leave at least 10 mm of venti lated space between the top of the stove and the chimney s insulation outer steel jacket see illustration The first section of the chimney is normally half insulated ap...

Page 9: ...harmful for both people and the environment BEFORE FIRING WHEN THE STOVE IS NEW During the first week firing can be started carefully Start with one to two fires during the first couple of days A par...

Page 10: ...t that you turn off the ventilation temporarily or open a window until the negative pressure has dissipated If there is insufficient burning material in the firebed to light a new fuel charge excessiv...

Page 11: ...NSIONS AND PERFORMANCE Height 820 mm Width 564 mm Depth 425 mm Weight 170 kg Height centre rear connection 665 mm Height top connection 820 mm Outer dimensions connection sleeve 125 mm Useful efficien...

Page 12: ...12 www keddy se Rev 1 01 05 2015...

Reviews: