background image

- 8 -

2. If the stove is to be connected at the rear, the 

back plate has to be removed by loosening the 

two Torx screws on the top. 

Then, loosen the flue connection using the two 

bolts inside the hearth. After this, turn the con

-

nection round and reassemble it again.

3. Dismantle the internal protective plate that 

sits on the inside of the back plate by pushing it 

up. (For rear connection, this plate must not be 

replaced.) Remove the thrust washer on the back 

plate by turning it backwards and forwards and 

then reinstall the back plate. Then, connect the 

stove connection to the flue (not included in the 

delivery) that connects to the chimney. Place the 

cover plate on the top of the stove to hide the 

chimney hole or, alternatively, a turned hotplate, 

(accessory). In which case, the cover plate is 

surplus to requirements.

4. If the chimney is to be installed on top, the 

chimney must be installed now. Connect the start 

module using sealant. Make sure that the joint is 

sealed.

NOTE! Always leave at least 10 mm of venti-
lated space between the top of the stove and 
the chimney's insulation/outer steel jacket. 
(see illustration)

The first section of the chimney is normally half-

insulated (approx. 30-mm insulation). However, 

where it passes through the joists, the chimney 

becomes fully insulated (approx. 60 mm of insu

-

lation). To maintain the distance of 100 mm from 

flammable walls, the chimney flue must be semi 

insulated. For additional information about the 

installation of the chimney, please, refer to the 

installation instructions for the brand of chimney 

you have selected. 

5. Install the hearth fittings. Begin with the hearth 

base and then install the vermiculite plates in the 

following order: 1. Back, 2. Rear left, 3. Baffle, 4. 

Rear right (now you need to push up the baffle), 

5. Front left, 6. Front right. The hearth plates 

should line up with the inside of the flange on the 

hearth base.

Finish by installing the enclosed log guard by 

hooking it firmly to the front edge of the hearth 

base.

 

You have now made your stove ready for use. In order for the sealant to harden properly, you must 
leave the stove for at least three days before firing it for the first time. 

Click!

Summary of Contents for K700

Page 1: ...K700 Installation Instructions Care and firing instructions...

Page 2: ...plate Outdoor air supply Flue Chimney connections PREPARATIONS 5 7 Flue connections for rear and top installation Floor plate and outdoor air connection Unpacking Dismantling INSTALLATION INSTRUCTION...

Page 3: ...sional perform the installa tion Our dealers can recommend suitable fitters You can find information about our dealers on www keddy se The Clean Air Act 1993 and Smoke Control Areas Under the Clean Ai...

Page 4: ...an use Keddy s own floor plate or floor glass These are installed after completing the installa tion of the stove OUTDOOR AIR SUPPLY For the combustion of wood air supply air is required The K700 can...

Page 5: ...stallation Alternative 2 Top installation Height from the floor to the centre of the flue at the rear 665 mm Height from the floor to the height of the connection top 820 mm Outer diam of the rear top...

Page 6: ...he connecting pipe passes through a flammable wall The flammable wall therefore must be furnished with a shaft with fire retardant lining Masterboard Minerit or equivalent and be insulated with at lea...

Page 7: ...heck horizontally and vertically with the help of a spirit level is on the hearth s sealing plate Tip The stove is vertical and horizontal when the door stays open at an opening an gle greater than 90...

Page 8: ...s leave at least 10 mm of venti lated space between the top of the stove and the chimney s insulation outer steel jacket see illustration The first section of the chimney is normally half insulated ap...

Page 9: ...harmful for both people and the environment BEFORE FIRING WHEN THE STOVE IS NEW During the first week firing can be started carefully Start with one to two fires during the first couple of days A par...

Page 10: ...t that you turn off the ventilation temporarily or open a window until the negative pressure has dissipated If there is insufficient burning material in the firebed to light a new fuel charge excessiv...

Page 11: ...NSIONS AND PERFORMANCE Height 820 mm Width 564 mm Depth 425 mm Weight 170 kg Height centre rear connection 665 mm Height top connection 820 mm Outer dimensions connection sleeve 125 mm Useful efficien...

Page 12: ...12 www keddy se Rev 1 01 05 2015...