K800 TECHNICAL SPECIFICATION

DIMENSIONS AND PERFORMANCE

Height                                                        1060 mm

Width                                                        392.5 mm

Depth                                                           400 mm

Weight K815                                                125 kg

Weight K825/835                                         135 kg

Height, centre rear connection                    920 mm

(If installed with floor glass)                         926 mm

Height, top connection                               1060 mm

Outer dimensions, connection sleeve       Ø150 mm

Useful efficiency                                             73 %

Rated output                                               6 - 7 kW

License number: 378 016

Summary of Contents for K800 Series

Page 1: ...K800 Installation instructions Care and firing instructions ...

Page 2: ... Floor plate Outdoor air supply Flue Chimney connections PREPARATIONS 5 8 Flue connections for rear and top installation Floor plate and outdoor air connection Unpacking INSTALLATION INSTRUCTIONS 9 11 CARE FIRING INSTRUCTIONS 12 14 TECHNICAL SPECIFICATION 15 Dimensions and performance Dimension drawings CERTIFICATES 15 2 ...

Page 3: ...in accordance with the documents that form the basis for the respective certificates and their associated requirements for production inspections IMPORTANT POINTS Contact the Planning and Building Committee in your municipality concerning the building notice It is also recommended that you contact a certified chimney sweep prior to installation NOTE Read through all of the installation instruction...

Page 4: ...an use Keddy s own floor plate or floor glass These are installed after completing the installation of the stove OUTDOOR AIR SUPPLY The combustion of wood requires air supply air The K800 can be provided with an external air supply which is recommended for properties with mechani cal ventilation see also under the heading Good to know on page 13 A sheet metal drum is used for drawing an outdoor ai...

Page 5: ... flue Alternative 1 Rear installation Alternative 2 Top installation Height from the floor to the centre of the flue at the rear 920 mm Height from the floor to the height of the connection top 1060 mm Note If you install Keddy s floor glass the di mensions above must be extended by 6 mm i e they become 926 and 1066 mm Outer diam of the rear top sleeve connection Ø150 For so called top connection ...

Page 6: ...insulated with at least 100 mm thick fireproof insulation around the connection pipe Thus there must not be any flammable material closer than 100 mm from the flue When the outer diameter of the flue is Ø153 mm the shaft must be at least 353 mm x 353 mm 3 UNPACKING DISMANTLING The K800 broadly speaking is supplied completely assembled regardless of the model 815 825 or 835 In the vast majority of ...

Page 7: ...nal since the lock can be operated using the glove by press ing directly on the lock hasp on the lower right of the door NOTE To close the door push it closed without lifting the lock hasp 2 Remove the log guard the grate and the ash pan 3 Remove the hearth plates Begin by pressing the smoke shelf upwards so you can remove one of the side plates After this remove in order the smoke shelf the secon...

Page 8: ...om falling on the floor Please note that the lower part of the cast iron panel are located with two heels that fit into two holes in the stove body If the panel is made of stone concrete there a groove that locates onto two elevations in the stove body You have now removed all of the necessary parts and can unscrew the stove and move it into the house NOTE Because the stove is heavy and is also eq...

Page 9: ... fit into the pre punched holes in the four corners of the plate If outdoor air is to be connected from below the cover plate on the bottom plate has to be removed and the 100 63 mm reduction piece installed before the stove is put into place 2 If the stove is to have a rear connection the back plate must be removed Loosen the two screws in the top corners Incline the back plate so it can be lifte...

Page 10: ... the stove on in order to protect the floor while manoeuvring it into position 4 Connect the outdoor air connection if any When the connection is from the rear the insulation sock needs to be shortened and then threaded on the hose inside the base Press the hose firmly onto the stove s supply air terminal 5 For a rear connected stove you now connect the prepared flue to the back connection sleeve ...

Page 11: ...comes fully insulated approx 60 mm of insulation For additional information about the installation of the chimney please refer to the installation instructions for the brand of chimney you have selected 8 Install the hearth plates the grate and the ash pan For illustration see points 2 and 4 on page 7 9 Assemble the base glass and connect the electric cable to the socket on the rear base plate You...

Page 12: ...r both people and the environment FIRING IN AUTOMATIC MODE The K800 is equipped with a feature that ensures that the firing is as safe and environmentally friendly as possible A heat probe which detects the outgo ing flue gas temperature is positioned in the top of the stove The probe sends a signal to a control unit which then automatically controls a damper to ensure the optimum combustion of th...

Page 13: ...s new a certain smell can arise This is caused by the paint and anti corrosion agent hardening Ensure good airing and the smell will disappear after the stove has been fired a couple of times Open a window near the stove if there is negative pressure in the house Leave the window open until the fire starts to burn normally Light the fire in the fol lowing way Automatic mode 1 Open the door Put in ...

Page 14: ...n relation to the ad ditional oxygen supply and wait before adding more wood until the old fire has burnt out REMOVAL OF SOOT AND MAINTENANCE Soot must be removed at least once per season The soot from the chimney and the connections should be removed by a chimney sweep The smoke shelf and the vertical hearth plates must be removed during sweeping You will find instructions on how this is done und...

Page 15: ...dth 392 5 mm Depth 400 mm Weight K815 125 kg Weight K825 835 135 kg Height centre rear connection 920 mm If installed with floor glass 926 mm Height top connection 1060 mm Outer dimensions connection sleeve Ø150 mm Useful efficiency 73 Rated output 6 7 kW License number 378 016 ...

Page 16: ...www keddy se Rev 5 26 05 2011 ...

Reviews: