Synopsis
(show)>
ping-check
[ ‹
profile_name
› ]
Arguments
Description
Value
Argument
Profile name.
String
profile_name
Example
(show)> ping-check
pingcheck:
profile: TEST
host: 8.8.8.8
port: 80
max-fails: 7
timeout: 1
mode: connect
interface: ISP
fail count: 0
status: pass
pingcheck:
profile: TEST1
mode: icmp
pingcheck:
profile: TEST2
mode: icmp
History
Version
Description
The show ping-check command has been introduced.
2.04
3.84.39 show printers
Description
Show attached printer list.
Prefix no
No
Change settings
No
Multiple input
No
Synopsis
(show)>
printers
Example
(show)> printers
printers:
printer: Canon MF8300C Series