F96VTN and G96VTN: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
22
(SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.)
Unit Size:
0801716
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1595
1560
1530
1500
1470
1440
1405
1370
1340
1290
Cooling (SW2-8,7,6)
OFF
OFF
ON
625
555
495
425
360
300
See Note 4
OFF
ON
OFF
810
755
700
645
595
540
480
425
380
330
OFF
ON
ON
1040
995
950
900
860
815
770
725
680
630
ON
OFF
OFF
1215
1175
1135
1095
1055
1015
975
935
900
860
ON
OFF
ON
1390
1355
1320
1285
1245
1210
1175
1140
1105
1070
ON
ON
OFF
1595
1560
1530
1500
1470
1440
1405
1370
1340
1290
ON
ON
ON
1790
1760
1735
1700
1655
1610
1570
1485
1395
1295
Maximum Clg Airflow
2
1790
1760
1735
1700
1655
1610
1570
1485
1395
1295
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Clg Default:
OFF
OFF
OFF
625
555
495
425
360
300
See Note 4
Low-Cooling (SW2-5,4,3)
OFF
OFF
ON
625
555
495
425
360
300
See Note 4
OFF
ON
OFF
810
755
700
645
595
540
480
425
380
330
OFF
ON
ON
1040
995
950
900
860
815
770
725
680
630
ON
OFF
OFF
1215
1175
1135
1095
1055
1015
975
935
900
860
ON
OFF
ON
1390
1355
1320
1285
1245
1210
1175
1140
1105
1070
ON
ON
OFF
1595
1560
1530
1500
1470
1440
1405
1370
1340
1290
ON
ON
ON
1790
1760
1735
1700
1655
1610
1570
1485
1395
1295
Cont. Fan Default:
OFF
OFF
OFF
625
555
495
425
360
300
See Note 4
Continuous Fan (SW2-5,4,3)
OFF
OFF
ON
465
390
300
See Note 4
OFF
ON
OFF
625
555
495
425
360
300
See Note 4
OFF
ON
ON
690
630
570
510
445
385
See Note 4
ON
OFF
OFF
690
630
570
510
445
385
See Note 4
ON
OFF
ON
690
630
570
510
445
385
See Note 4
ON
ON
OFF
690
630
570
510
445
385
See Note 4
ON
ON
ON
690
630
570
510
445
385
See Note 4
Heating (SW1)
High Heat Airflow
3
1470
1435
1400
1365
1330
1295
1260
1225
1190
1155
Low Heat Airflow
3
1150
1110
1070
1030
990
950
910
870
830
790
(SW1-5 and SW2-2 set to OFF, except as indicated. See Notes 1 and 2.)
Unit Size:
1002120
Clg/CF Switch settings
External Static Pressure (ESP)
Clg Switches:
SW2-8
SW2-7
SW2-6
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Clg Default:
OFF
OFF
OFF
1890
1845
1800
1755
1700
1655
1610
1560
1510
1460
Cooling (SW2-8,7,6)
OFF
OFF
ON
1015
825
630
485
405
325
See Note 4
OFF
ON
OFF
1080
895
815
740
690
615
555
475
See Note 4
OFF
ON
ON
1155
1080
1020
940
890
825
785
710
660
590
ON
OFF
OFF
1310
1260
1195
1140
1075
1025
970
925
875
810
ON
OFF
ON
1520
1475
1425
1365
1315
1255
1210
1155
1110
1055
ON
ON
OFF
1890
1845
1800
1755
1700
1655
1610
1560
1510
1460
ON
ON
ON
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
Maximum Clg Airflow
2
2290
2230
2160
2085
2005
1915
1820
1730
1640
1525
CF Switches
SW2-5
SW2-4
SW2-3
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Low-Clg Default:
OFF
OFF
OFF
1015
825
630
485
405
325
See Note 4
Low-Cooling (SW2-5,4,3)
OFF
OFF
ON
745
640
535
See Note 4
OFF
ON
OFF
1015
825
630
485
405
325
See Note 4
OFF
ON
ON
1080
895
815
740
690
615
555
475
See Note 4
ON
OFF
OFF
1155
1080
1020
940
890
825
785
710
660
590
ON
OFF
ON
1310
1260
1195
1140
1075
1025
970
925
875
810
ON
ON
OFF
1520
1475
1425
1365
1315
1255
1210
1155
1110
1055
ON
ON
ON
1890
1845
1800
1755
1700
1655
1610
1560
1510
1460
Cont. Fan Default:
OFF
OFF
OFF
1015
825
630
485
405
325
See Note 4
Continuous Fan (SW2-5,4,3)
OFF
OFF
ON
745
640
535
See Note 4
OFF
ON
OFF
1015
825
630
485
405
325
See Note 4
OFF
ON
ON
1080
895
815
740
690
615
555
475
See Note 4
ON
OFF
OFF
1155
1080
1020
940
890
825
785
710
660
590
ON
OFF
ON
1155
1080
1020
940
890
825
785
710
660
590
ON
ON
OFF
1155
1080
1020
940
890
825
785
710
660
590
ON
ON
ON
1155
1080
1020
940
890
825
785
710
660
590
Heating (SW1)
High Heat Airflow
3
1905
1865
1825
1775
1730
1685
1640
1590
1545
1490
Low Heat Airflow
3
1480
1435
1375
1330
1265
1215
1160
1115
1060
1005
Table 9 – Cooling
4
and Heating Air Delivery - CFM (Bottom Return
5
with Filter) (Continued)