ECLIPSE – INSTALLATION/OPERATION MANUAL
Eclipse
Jan-10
12
3.0 BURNER
SPECIFICATIONS
CLASSIC AIR
Model Burner
Input
Nozzle
Pump
(psi)
Air
Setting
Turbulator
Output
Heating CFM@ Blower Speed
USGPH L/h Btu/h
Btu/h kW 0.2"wc 0.5"wc 0.2"wc 0.5"wc
KMR(F)-E1-0095-03
Riello 40 F3
0.61 2.32 85,400
0.50 60W
150 2.7
0.5
73,000
21
1084
873
4 Lo
4 Lo
0.73 2.78
102,200 0.60 60W
150 3.3
1.0
87,000
25
1084
1113
4 Lo
2 MHi
0.80 3.04
112,000 0.65 60W
150 3.8
1.2
95,000
28
1198
1200
3 MLo
1 Hi
KMR(F)-G3-0095-03
Beckett AFG
PA 402
0.59 2.24 82,600
0.50 70B 140 6.5**
70,000
21
1084
873
4 Lo
4 Lo
0.71 2.70 99,400
0.60 70B 140 6.5
84,000
25
1084
1113
4 Lo
2 MHi
0.77 2.93
107,800 0.65 70B 140 7.5
92,000
27
1198
1200
3 MLo
1 Hi
Direct Vent
KMR(F)-V1-0095-03
Riello 40 BF3
0.61 2.32 85,400
0.50 80W
150 3.6
1.0
73,000
21
1084
997
4 Lo
3 MLo
0.73 2.78
102,200 0.60 80W
150 4.0
1.5
87,000
25
1084
1200
4 Lo
1 Hi
0.80 3.04
112,000 0.65 70W
150 4.8
2.0
95,000
28
1198
1200
3 MLo
1 Hi
KMR(F)-D2-0095-03
Beckett AFG
PA 404*
0.59 2.24 82,600
0.50 70B 140 45**
***
70,000
21
1084
997
4 Lo
3 MLo
0.71 2.70 99,400
0.60 70B 140
55
***
84,000
25
1084
1200
4 Lo
1 Hi
0.77 2.93
107,800 0.65 70B 140
67
***
92,000
27
1198
1200
3 MLo
1 Hi
*Post Purge factory set to two minutes.
**Low Firing Rate Baffle required.
***Use Air Boot Restrictor Plate.
EVO
*Post Purge factory set to two minutes.
**Low Firing Rate Baffle required.
***Use Air Boot Restrictor Plate.
****Approximately 90 Btu/h CFM.
MAX
Model Burner
Input
Nozzle
Pump
(psi)
Air
Setting
Turbulator
Output Heating
USGPH L/H Btu/h
Btu/h kW
CFM
KMR(F)-E1-0095-E3
Riello 40 F3
0.61
2.32
85,400 0.50
60W
150
2.7
0.5
73,000 21
810*
0.73
2.78
102,200 0.60
60W
150
3.3
1.0
87,000 25
970*
0.80
3.04
112,000 0.65
60W
150
3.8
1.2
95,000 28
1055*
Direct Vent
KMR(F)-V1-0095-E3
Riello 40 BF3
0.61 2.32 85,400 0.50
80W 150
3.6
1.0
73,000
21
810*
0.73 2.78 102,200 0.60 80W 150
4.0
1.5
87,000
25
970*
0.80 3.04 112,000 0.65 70W 150
4.8
2.0
95,000
28
1055*
*Approximately 90 Btu/h CFM.
The turbulator and air settings found on this page should be used as a guide.
Model Burner
Input
Nozzle
Pump
(psi)
Air
Setting
Turbulator
Output Heating
USGPH
L/h Btu/h
Btu/h kW CFM****
KMR(F)-E1-0095-F3
Riello 40 F3
0.61
2.32
85,400 0.50
60W
150
2.7
0.5
73,000 21 810****
0.73
2.78
102,200 0.60
60W
150
3.3
1.0
87,000 25 970****
0.80
3.04
112,000 0.65
60W
150
3.8
1.2
95,000 28 1055****
KMR(F)-G3-0095-F3
Beckett
AFG PA
402
0.59
2.24
82,600 0.50
70B
140
6.5/0.0**
***
70,000 21 780****
0.71
2.70
99,400 0.60
70B
140
6.5/0.0
***
84,000 25 930****
0.77
2.93
107,800 0.65
70B
140
7.5/0.0
***
92,000 27 1020****
Direct Vent
KMR(F)-V1-0095-F3
Riello 40
BF3
0.61 2.32
85,400
0.50
80W 150
3.6
1.0
73,000 21
810****
0.73 2.78 102,200 0.60 80W 150
4.0
1.5
87,000 25
970****
0.80 3.04 112,000 0.65 70W 150
4.8
2.0
95,000 28
1055****
KMR(F)-D2-0095-F3
Beckett
AFG PA
404*
0.59 2.24
82,600
0.50
70B 140 4.5**
***
70,000
21 780****
0.71 2.70
99,400
0.60
70B 140
55
***
84,000 25
930****
0.77 2.93 107,800 0.65 70B 140
67
***
92,000 27 1020****