Gen 3 Cooling Coils  

Inserting the Cooling Coil Kit is optional and for this reason, the ports for the Cooling Coil will need to be 

manually drilled into the lid. To insert the cooling coils:  

1.

 

Drill two 13mm diameter holes through the indentations marked on the lid.

 

2.

 

Protrude the Cooling Coil Posts from the bottom of the Apollo lid so that the male threads are facing 
upward with the O-rings on the underside. 

3.

 

Secure each post by screwing the Cooling Coil Nut onto the male thread. 

4.

 

The Cooling Coil connects to the Gen 3 Lid by pushing the ends through the Cooling Coil Posts. Adjust 
the seating level of the Cooling Coil to finish. 

 

Gen 3 CIP Cleaning Kit  

CIP stands for Clean in Place. Our optional Fermenter King Gen 3 Cleaning Kit includes the following 

parts to provide brewers with a powerful CIP system for getting their tanks sparkling clean without 

scrubbing. The required parts are:  

 

½ BSP Female Hose Barb (5717) 

 

½ BSP Stainless Steel Spray-ball (9162-2) 

 

2 meters of Silicone Tube Hose 12.5mm x 18.5 mm (5496) 

 

70W submersible pump (8051-1) 

 

15L bucket (8051-5) 

 

Gen 3 Cleaning Kit Operation  

1.

 

Remove all fittings from the tank except the lid and neck ring and place them in the 15L bucket. 

2.

 

The pump comes pre-packed with a black hose barb. This is to be screwed onto the outlet of the 
submersible pump. Place the pump in the middle of the bucket. 

3.

 

Attach the CIP Spray-ball to the underside of the lid. 

4.

 

Attach the ½ BSP female hose barb to the top side of the lid. 

5.

 

Link the silicone tubing from the barbed pump outlet to the barb at the top of the fermenter lid. 

6.

 

Fill the tank with 5 litres of warm water at no higher than 50°C and Atomic 15 ABC (9006) or other 
recommended cleaner mixed to the recommended dosage. 

7.

 

Seat the bucket right underneath the tank. 

8.

 

Run the pump to drive the cleaning solution through the spray-ball until no fermentation residue is 
noticeable on the interior surfaces of the tank. 

9.

 

Rinse with clean water. 

 

Storage  

After each fermentation, it is a best practice to clean and sanitise the Apollo fermenter, then store dry. 
We recommend pressurising the tank to 10 psi and storing in a cool room away from sunlight. This ensures 
that your tank stays free from oxygen and bacteria for up to 2 weeks.  
 
 

Summary of Contents for APOLLO SNUB NOSE

Page 1: ...Nose User Manual https www kegking com au Keg King is a registered business name of MCH Australia Pty Ltd Last Update 21 February 2023 APOLLO SNUB NOSE 30L 60L P E T Pressure Fermenters User Instruct...

Page 2: ...tastrophic damage to the unit property and users Always ensure adequate pressure relief is attached to the unit and gradual pressure increases are monitored and regulated WARNING DO NOT expose the tan...

Page 3: ...s name of MCH Australia Pty Ltd Table of Contents Warnings and General Safety 2 Keg King 4 Introduction 5 Features 5 Fermenter Assembly 6 General Operation 7 Leak Test 7 Cleaning and Sanitation 7 Ferm...

Page 4: ...ur brands include King Kegs our Australian Made P E T kegs Apollo P E T Pressure Fermenters Unitanks KegMaster Kegerators Atomic 15 Brewery Cleaners UltraTap Twist FC Faucets Spundy spunding valves th...

Page 5: ...help brewers brew even better beer than before since sanitation is key to brewing great beer in the first place Much like a bung or sink plug the Plunger Valve closes off the bottom of the fermenter b...

Page 6: ...s in the lid 4 Insert a Universal Poppet into each ball lock post 5 Tighten down the liquid and gas posts to the thread ball lock post ports on the lid it does not matter which side you choose to plac...

Page 7: ...o below 30 C prior to transfer to the Apollo tank After pitching in the yeast close up the tank and ferment with controlled temperature and pressure To control Apollo s internal pressure we recommend...

Page 8: ...ay ball 9162 2 2 meters of Silicone Tube Hose 12 5mm x 18 5 mm 5496 70W submersible pump 8051 1 15L bucket 8051 5 Gen 3 Cleaning Kit Operation 1 Remove all fittings from the tank except the lid and ne...

Reviews: