The Temperature Control Panel
Code Function
Set Range
Recommended value
F1
Temperature set value
-50 to 99°C
The yeast fermentation
temperature (e.g. 18°C)
F2
Hysteresis
1 to 10°C
0.5°C
F3
Compressor / Cooling delay
1 to 10 minutes 0 minutes
F4
Temperature calibration value
-10 to +10°C
0°C
Instructions
Power ON:
hold for 5 seconds.
Power OFF:
hold for 3 seconds
During normal operation, the screen displays the
real-time temperature
(
RT
)
The controller switches between heating and cooling modes.
Cooling Mode:
when
RT
≥
ST (set temperature) + F2 (hysteresis value)
During Cooling mode, the Cooling Indicator is illuminated.
If the
Cooling Indicator is flashing
, it indicates the cooling equipment is undergoing the
compressor / cooling delay (not necessary for this unit).
When
RT
≤ ST
the cooling stops, and the Cooling Indicator is no longer illuminated.
Heating Mode:
when
RT ≤
ST (set temperature)
–
F2 (hysteresis value)
During Heating mode, the Heating Indicator is illuminated.
When
RT ≥ ST
, the heating stops, and the Heating Indicator is no longer illuminated.
Example:
ST
is set to 10°C, and
F2
is set to 3°C
Cooling Mode starts when
RT ≥
13°C
and stops when
RT ≤
10°C
Heating Mode starts when
RT ≤
7°C
and stops when
RT ≥
10°C
Specifications
Temperature measuring range:
-50~99°C
Resolution:
0.1°C
Accuracy:
±1°C (-50~70°C)
Sensor error delay:
1 minute
Power supply:
12V DC
Power consumption:
≤
3W
Sensor:
NTC sensor (1PC)
Relay contact capacity:
Cool 10A/250VAC; Heat 10A/250VAC
Ambient temperature:
0~60°C
Storage temperature:
-30~75°C
Relative humidity:
20%~85% (No condensate)
Power ON & OFF
Confirm & save the set value
Set key, Entry and Set parameter
Increase value / Select Function
Decrease value / Select Function
Cool
Cooling indicator
Heat
Heating indicator
Set
Setting indicator