19
ELECTRICAL CONFIGURATION
Beverage Factory recommends that this product be installed by a licensed and qualified electrician in accordance with all
applicable national, state, provincial, and local electrical codes. As with all electrical appliances, under no circumstances
should you attempt to install, repair, or disassemble this water heater without first shutting off all power to the unit
directly at the fuse or breaker box. Make sure to shut off all breakers. SERIOUS BODILY INJURY OR DEATH COULD OCCUR
IF YOU IGNORE THIS WARNING.
All wiring (wire gauge) and circuit protection (breakers) must comply with the U.S. National Electrical Code (NEC) in the
USA, or the Canadian Electrical Code (CEC) in Canada. Failure to do so could result in property damage and/or personal
injury, and void your warranty.
Electrical specifications
MODEL
VOLTAGE/PHASE
KW
TOTAL AMPS
RECOMMENDED
WIRE SIZE (CU) 90° C
RECOMMENDED MINIMUM BREAKER
SIZE (PER NEC
–
INTERMITTENT DUTY)
KC HDT301
240 1
Φ
Δ
4.8
20
14
20
230 1
Φ
Δ
4.4
20
14
20
208 1
Φ
Δ
3.6
18
14
20
Electrical Plug Installation
The HOT DRAFT® Tower will arrive without an electrical plug installed at the end of the power cable. We recommend a
plug to be installed by a licensed and qualified electrician. Ensure the plug matches the power outlets found in your
installation location.