Cleaning Procedure 

1.

 

To clean your Hot Draft® 

Tower, set the unit to “Cleaning Mode” (see section 

Navigating your Hot Draft

®

 Tower 

on 

page 9). This will disable the heating process and allow for cleaning solution to pass through the Hot Draft® 
components. Failure to do so may result in the formation of toxic vapors and gases. Avoid inhalation, use personal 
protective equipment, and work in a well-ventilated area.  
 

2.

 

Begin by filling your cleaning container with diluted cleaning chemical, as directed by the specifications on the cleaning 
chemical label. Follow 

all your cleaning chemical’s safety instructions and directions. 

When diluting chemical 

concentrate, always add chemical to water and never add water to chemical. FAILURE TO DO SO MAY RESULT IN 
SERIOUS BODILY INJURY.  
 

3.

 

Disconnect your kegs from the Hot Draft® Tower. Hook up your cleaning container, filled with diluted cleaning 
chemical, to a Hot Draft® beverage line. 

Refer to your cleaning container’s instructions 

on connecting to a dispense 

system. Some disassembly may be required. 
 

4.

 

Place a bucket or pitcher under the faucet corresponding to the beverage line* connected to your cleaning container. 
Open the faucet and allow the cleaning solution to run through the lines as if pouring a beverage. Repeat for all 
beverage lines**.  
* Refer to page 16 of this manual to identify the faucets and corresponding beverage lines.  
** If cleaning solution is not pouring from the Hot Draft® Faucet, 

ensure that the unit is set to “Cleaning Mode”. 

 

 

5.

 

VERY IMPORTANT: Rinse out the lines with clean water before serving a beverage again. When the cleaning container 
is empty, rinse and fill with fresh water. Repeat step 4 with fresh water. 
 

6.

 

Disconnect your cleaning container from the Hot Draft® Tower and hook up your kegs. Some reassembly may be 
required. 

Exit “Cleaning Mode” (see section 

Navigating your Hot Draft

®

 Tower 

on page 9) to re-enable the heating 

process. The unit is now ready to heat and dispense your beverage.  

Cleaning and Maintenance Schedule 

Every 2 weeks, disassemble and clean all faucets. Scrub clean all keg couplers and tapping devices. 

Every 3 months or between switching kegs, clean your beverage lines with a chemical cleaner solution. 

Every year, replace your vinyl jumpers and vinyl direct draw lines.  

 

 

 

Summary of Contents for Hot Draft KC HDT301

Page 1: ...USER MANUAL Model KC HDT301...

Page 2: ...L SPECIFICATIONS 6 PRODUCT FEATURES 6 PARTS DIAGRAM 7 NAVIGATING YOUR HOT DRAFT TOWER 8 Accessing the Service Menu 8 SETPOINT 8 PURGE 9 CLEAN 9 FLOW PWM IN OUT VERSION 9 COMP 9 POURING WITH YOUR HOT D...

Page 3: ...oupling the keg so that pressure is eliminated during the cleaning inspection THIS PRODUCT SHOULD BE INSTALLED BY A LICENSED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE P...

Page 4: ...reaker lockout must be used Ref NEC 422 31 7 If the Tower is installed in a location where liquid damage could occur in the event of a leak it is recommended that a drip pan be installed and connected...

Page 5: ...at its original maximum quality without the degradation of heretofore constant reheating What does this mean The HOT DRAFT Tower delivers constant freshness with zero waste Inside the keg nitrogen is...

Page 6: ...8 kW 240 V 60 Hz 20A 4 4 kW 230 V 60 Hz 20A 3 6 kW 208 V 60 Hz 18A Operating Pressure Range Optimal Operating Pressure Range 20 PSI 40 PSI 25 PSI 35 PSI Minimum Flow Rate 0 15 GPM Minimum Maximum Inl...

Page 7: ...4 Outlet Thermistor 5 ECO Electrical Cutoff 6 Heating Chamber 7 Inlet Manifold 8 Triac 9 Inlet Thermistor 10 Hall Effect Sensor 11 Flow Meter 12 Inlet Screen 13 Inlet Barbed Nipple for 3 16 ID Tubing...

Page 8: ...exit the Service Menu you must navigate to either the FLOW PWM IN OUT or VERSION screens and press SEL You cannot exit the Service Menu from the SETPOINT PURGE or CLEAN screens SETPOINT SETPOINT will...

Page 9: ...aft faucet to run your cleaning solution through the Hot Draft lines Pressing SEL will return you back to the service menu FLOW PWM IN OUT VERSION FLOW displays the flow rate of the Hot Draft line dis...

Page 10: ...beverage 1 Before Pouring your first cup you must purge the Hot Draft Tower Failure to do so may cause hot water to splash on the first pour Navigate to the Purge setting in the Service Menu and turn...

Page 11: ...ep the faucet open while the unit is heating the beverage The Hot Draft Tower may drip out underheated beverage during heating This is normal keep a mug under the Hot Draft faucet to catch these drips...

Page 12: ...erage is pouring accurately to the setpoint temperature For a 208V electrical system we recommend tuning the Compensation Factor between 10 18 Flow Rate Fine tuning the Flow Rate may be required if th...

Page 13: ...FORE REMOVING LID AND REACHING INSIDE FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH To remove the lid use a Philips head screwdriver to remove 4 screws circled in red below Flow rate is adjus...

Page 14: ...shown below After adjusting the flow adjustment spindle check the flow rate by plugging in the unit navigating to FLOW in the service menu and opening the hot beverage faucet to pour a beverage Adjust...

Page 15: ...raft heating components from potent acids found in this product To clean lines used to dispense beverages such as beer or kombucha we recommend Kegco Beer Line Cleaner This solution will remove organi...

Page 16: ...cting to a dispense system Some disassembly may be required 4 Place a bucket or pitcher under the faucet corresponding to the beverage line connected to your cleaning container Open the faucet and all...

Page 17: ...omer service Underheated Inconsistent Beverage Pour The unit is not supplied with enough voltage Verify power supply voltage Ensure DIP Switches are correctly configured as shown in section Electrical...

Page 18: ...ressed or implied whether written or oral including but not limited to warranties of merchantability and fitmess for a particular purpose Kegco expressly disclaims the implied warranties of merchantab...

Page 19: ...control o The product has been removed from its original installation location o The product has been used for other than the intended purpose The original owner and not Kegco or its agent representa...

Reviews:

Related manuals for Hot Draft KC HDT301