background image

 

User Manual for

 

HOT DRAFT®

  

 

 

8510 Miralani Dr.  

San Diego, CA 92126 

(888) 980 - 4810 

support@kegco.com 

 

19 

WHAT IS NOT COVERED: 

 

Kegco is not liable for any damage or other damages arising, directly or indirectly, from any defect in product 
component part(s) or from its use. 

 

Kegco is not liable under this limited warranty or otherwise if: 

o

 

The product or any of its component parts have been subject to misuse, alteration, neglect, or accident. 

o

 

The product has not been installed in accordance with the applicable local plumbing and/or building 
code(s) and/or regulation(s). 

o

 

The product has not been installed or maintained in accordance with Kegco’s printed instruct

ion, or 

installed with improper orientation, improper fastening, improper use of pipe dope/plubers putty or with 
the use of any non-Kegco approved sealant. 

o

 

The product has not been continuously supplied with liquid or the liquid’s inlet temperature is abov

Kegco’s recommended maximum temperature.

 

o

 

The product experiences any pressure or flow interruptions, normal inlet pressure is outside of the 
published specification for the product; is exposed to any condition that causes the product to turn on 
before the air is purged from the product also known as a dry-fire. 

o

 

The product has been exposed to conditions resulting from floods, earthquakes, winds, fire, freezing, 

lightning, or circumstances beyond Kegco’s control.

 

o

 

The product has been removed from its original installation location. 

o

 

The product has been used for other than the intended purpose.  

 

The original owner, and not Kegco or its agent/representative, is liable for and shall pay for all field charges for 
labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the 
original owner in order to repair the product. 
 

Subject to ther terms and conditions set forth in this limited warranty, if the product fails or leaks because of defects in 

materials or Kegco’s wo

rkmanship during the applicable warranty period set forth above, the original owner should 

contact Kegco for a Returned Merchandise Authorization (RMA). No returns will be accepted by Kegco without an RMA 
number and Kegco assumes no responsibility for a product returned without an RMA number. Products should be 
wrapped and packaged securely to avoid shipping damage. All shipments of parts from Kegco to the original owner to 
replace defective components shall be made via normal ground transportation. If expedited shipment is required, it will 

be provided at the original owner’s additional cost.

 

SERVICE FOR YOUR HOT DRAFT® TOWER:  

With the purchase of your Kegco appliance, you can have the confidence that if you ever need additional information or 
assistance, the Kegco Customer Service team will be here for you. Whatever your questions are about our products, help 
is available. Just call us toll-free.  

KEGCO PRODUCT CUSTOMER SERVICES:  

Product Information, Part Orders and In-Home Repair Service:  888-980-4810  

Summary of Contents for Hot Draft KC HDT301

Page 1: ...USER MANUAL Model KC HDT301...

Page 2: ...L SPECIFICATIONS 6 PRODUCT FEATURES 6 PARTS DIAGRAM 7 NAVIGATING YOUR HOT DRAFT TOWER 8 Accessing the Service Menu 8 SETPOINT 8 PURGE 9 CLEAN 9 FLOW PWM IN OUT VERSION 9 COMP 9 POURING WITH YOUR HOT D...

Page 3: ...oupling the keg so that pressure is eliminated during the cleaning inspection THIS PRODUCT SHOULD BE INSTALLED BY A LICENSED ELECTRICIAN AND A QUALIFIED PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE P...

Page 4: ...reaker lockout must be used Ref NEC 422 31 7 If the Tower is installed in a location where liquid damage could occur in the event of a leak it is recommended that a drip pan be installed and connected...

Page 5: ...at its original maximum quality without the degradation of heretofore constant reheating What does this mean The HOT DRAFT Tower delivers constant freshness with zero waste Inside the keg nitrogen is...

Page 6: ...8 kW 240 V 60 Hz 20A 4 4 kW 230 V 60 Hz 20A 3 6 kW 208 V 60 Hz 18A Operating Pressure Range Optimal Operating Pressure Range 20 PSI 40 PSI 25 PSI 35 PSI Minimum Flow Rate 0 15 GPM Minimum Maximum Inl...

Page 7: ...4 Outlet Thermistor 5 ECO Electrical Cutoff 6 Heating Chamber 7 Inlet Manifold 8 Triac 9 Inlet Thermistor 10 Hall Effect Sensor 11 Flow Meter 12 Inlet Screen 13 Inlet Barbed Nipple for 3 16 ID Tubing...

Page 8: ...exit the Service Menu you must navigate to either the FLOW PWM IN OUT or VERSION screens and press SEL You cannot exit the Service Menu from the SETPOINT PURGE or CLEAN screens SETPOINT SETPOINT will...

Page 9: ...aft faucet to run your cleaning solution through the Hot Draft lines Pressing SEL will return you back to the service menu FLOW PWM IN OUT VERSION FLOW displays the flow rate of the Hot Draft line dis...

Page 10: ...beverage 1 Before Pouring your first cup you must purge the Hot Draft Tower Failure to do so may cause hot water to splash on the first pour Navigate to the Purge setting in the Service Menu and turn...

Page 11: ...ep the faucet open while the unit is heating the beverage The Hot Draft Tower may drip out underheated beverage during heating This is normal keep a mug under the Hot Draft faucet to catch these drips...

Page 12: ...erage is pouring accurately to the setpoint temperature For a 208V electrical system we recommend tuning the Compensation Factor between 10 18 Flow Rate Fine tuning the Flow Rate may be required if th...

Page 13: ...FORE REMOVING LID AND REACHING INSIDE FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH To remove the lid use a Philips head screwdriver to remove 4 screws circled in red below Flow rate is adjus...

Page 14: ...shown below After adjusting the flow adjustment spindle check the flow rate by plugging in the unit navigating to FLOW in the service menu and opening the hot beverage faucet to pour a beverage Adjust...

Page 15: ...raft heating components from potent acids found in this product To clean lines used to dispense beverages such as beer or kombucha we recommend Kegco Beer Line Cleaner This solution will remove organi...

Page 16: ...cting to a dispense system Some disassembly may be required 4 Place a bucket or pitcher under the faucet corresponding to the beverage line connected to your cleaning container Open the faucet and all...

Page 17: ...omer service Underheated Inconsistent Beverage Pour The unit is not supplied with enough voltage Verify power supply voltage Ensure DIP Switches are correctly configured as shown in section Electrical...

Page 18: ...ressed or implied whether written or oral including but not limited to warranties of merchantability and fitmess for a particular purpose Kegco expressly disclaims the implied warranties of merchantab...

Page 19: ...control o The product has been removed from its original installation location o The product has been used for other than the intended purpose The original owner and not Kegco or its agent representa...

Reviews:

Related manuals for Hot Draft KC HDT301