User Manual for
HOT DRAFT®
8510 Miralani Dr.
San Diego, CA 92126
(888) 980 - 4810
support@kegco.com
d
9
PURGE
“PURGE On/Off”
is the setting to toggle Purging Mode. Purging Mode will disable the heating chamber and allow you to
purge the Hot Draft® lines of any air pockets that may be affecting the outlet temperature.
Pressing “
SEL
” will
bring you to
a
screen where you can toggle Purging Mode “ON” or “OFF” by pressing either “Up” or “Down”.
While the screen displays
“PURGE ON”, open the
Hot Draft® faucet until all air pockets have been purged.
Pressing “Select” will return you back to
the service menu.
CLEAN
“CLEAN On/Off”
is the setting to toggle Cleaning Mode. Cleaning mode will disable the heating chamber and allow you to
clean the dispense system (see
Cleaning and Maintenance For Your Hot Draft® Tower
on page 15
). Pressing “
SEL
” will
bring you to a screen where you can toggle Cleaning Mode “ON” or “OFF” by pressing either “Up” or “Down”.
While the
screen displays “CLEAN ON”, open the Hot Draft® faucet to
run your cleaning solution through the Hot Draft® lines.
Pressing “
SEL
” wil
l return you back to the service menu.
FLOW, PWM, IN/OUT, & VERSION
“FLOW” displays the flow rate of the
Hot Draft® line, displayed in GPM (gallons per minute).
“PWM” displays the
power
output
of the heating element, displayed as a percentage. “IN/OUT” di
splays the temperature in degrees Fahrenheit at
the inlet and outlet of the Hot Draft® heating element, allowing you to monitor the outlet temperature of your beverage.
“VERSION” displays the current version number of the software.
NOTE: The “FLOW”, “PWM”,
“IN/OUT”, and “VERSION” options of the Service Menu cannot be changed and are displayed
for troubleshooting.
COMP
“COMP” displays the compensation factor
, displayed as a percentage, of the Hot Draft® heating element. This is used to
fine tune the outlet temperature of your Hot Draft® beverage.
To edit the compensation factor, press “SEL” and a
* will
appear next to the compensation factor. * indicates
that the temperature can be changed. Each press of either “Up” or
“Down” will increase or decrease the compensation factor by 2%, between –18% and +18%. Press “SEL” to
lock the