and open your tap to clean your tap and product line. Then rinse with water and repeat with
correctly diluted Stellarsan solution.
Homebright streak free stainless steal cleaner
and polish spray to clean the outside of the
Benchy Carbon to leave it looking shiny and new.
Page
8
of
9
Last Updated
13/12/2021 4:54 PM
Benchy
–
Glycol Instruction Manual
FAULT CODES
The power button is a multi-purpose button both turning on the main power to the compressor but
also the illumination on the button will flash to indicate fault codes if an error has been triggered.
Number of Flashes
Fault Type
1
Voltage Fault
(The input voltage is beyond the setting range)
2
Fan Fault Current
(The fan’s output current is more than 1A peak)
3
Compressor Start Fault
(The rotor is blocked or the system pressure is too
high (above 6 bar)
4
Minimum Motor Speed Fault
(If the compressor is too highly loaded and
cannot maintain minimum rotor speed this will be triggered, also if the
controller cannot sense rotor speed this will also trigger this fault code)