Benchy Sparkling - Instruction Manual
Page
8
of
16
Last Updated 3/06/2022 6:03 PM
Redirecting the SPARKLING OUT and CHILLED OUT Hosing
1.
Ensure the mains water and CO
2
gas supply are turned off or disconnected and the soda
carbonator keg is completely depressurised before removing any tubing from the push in
fittings.
2.
Remove the 4mm x 8mm EVABarrier tubing from the bulkhead of the sparkling water OUT
and cold still water OUT push in fittings on the back of the Benchy Sparkling. To correctly
remove the tubing from the push in fitting refer to the push in fittings instructions below.
3.
Cut down the EVABarrier tubing using a sharp Stanley knife or 2 in 1 tube cutter such that
the length is long enough to reach to the shank. Ensure the tubing is cut cleanly and straight
with no burs.
4.
Insert the sparkling water OUT and cold still water OUT tubing securely into the duotight
fittings on the back of the shanks. To correctly insert the tubing into the duotight fitting refer
to the
Benchy Sparkling - under bench dispensing plumbing
Remove hosing from SPARKLING OUT
AND CHILLED OUT push in fittings