RAPT Fermentation Chamber Instruction Manual
Page
11
of
13
www.KegLand.com.au
Last Updated 1/03/2022 4:36 PM
Unit System
This toggles the display between metric or imperial data
Zoom Level
This allows you to choose the date range displayed on the graph, from 1 to 28 days. The default
range is 7 days.
Cooling Hysteresis
You can set the cooling hysteresis range here (Range 1°C
–
10°C)
Heating Hysteresis
You can set the heating hysteresis range here (Range 1°C
–
10°C)
Compressor Cooldown
This sets the minimum allowed time between compressor operations (A
minimum
of 5 minutes is
recommended to avoid undue stress on the compressor)
Mode Switch Delay
This sets the minimum allowed time between mode changes (IE from Heating to Cooling). A
minimum of at least 30 minutes is often more suitable for fermentation to avoid unnecessary
heating/cooling operations.
Cooler Enabled
This toggles the cooling mode. When unchecked, the compressor will
not
operate irrespective of
other settings.
Heating Enabled
This toggles the heating mode. When unchecked, the heating will
not
operate irrespective of other
settings.
Fan Always On
When unchecked, the fan will only operate during active heating or cooling. Keeping the fan on will
ensure a more even top to bottom temperature if fermenting more than one beer, for example.
Light On
The light can be toggled between Always On, Always Off and Automatic (recommended)
Sounds Enabled
Toggles the sounds on or off.