2 Point Calibration
Please refer to
“Calibration” section
NTC Beta
Here you can enter the NTC Beta of an external temperature probe, if known. The default is 3950
NTC Ref Temperature
Here you can enter the NTC Ref Temperature of an external temperature probe, if known. The
default is 298.2
NTC Ref Resistance
Here you can enter the NTC Ref Resistance of an external temperature probe, if known. The default
is 100000
PID Heating
This will toggle PID heating mode on or off. Note
–
PID control is recommended for advanced users,
and is not required for typical fermentation.
PID Cycle Time
Enter PID cycle time (in seconds)
PID P Coefficient
Enter desired proportional PID coefficient
PID I Coefficient
Enter desired integral PID coefficient
PID D Coefficient
Enter desired derivative PID coefficient
Forget WiFi Config
This will disconnect the RAPT Chamber from the network and forget current wifi settings. It will also
restart the device.
Disable WiFi
This will disconnect the RAPT Chamber from the network and disable the WiFI. It will also restart the
device.