3 Installation
PV Grid-tied Inverter SPI-B X2 Series (8K-25K)
User Manual
28
All rights reserved ©Xiamen Kehua Digital Energy
Tech Co., Ltd.
WiAPP can communicate with inverter through WIFI/4G stick to realize the local and remote
maintenance. User can perform the information query, alarm query, event query, parameter setting, etc.
of inverter through Wi APP.
Download and install WiAPP:
Method 1: search Wi and download the Wi APP through the following
application market, and install the Wi APP.
1.
Application market (Android Chinese user) ;
2.
APP store (iOS) .
Method 2: scan the QR code below to download and install the Wi APP according to
prompting.
----End
3.5.6 COM. Communication Connection (Optional)
COM. interface can be set to DRM and RS485 communication interface, they all adopt RJ45 plug to
connect. The pin definition of RJ45 plug is as shown in Figure3-28.
1--8
RJ45 plug
RJ45 interface
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Pin definition of RJ45 plug:
PIN 1: White orange - DRM 5
PIN 2: Orange - DRM 6
PIN 3: White green - DRM 7
PIN 4: Blue - DRM 8
PIN 5: White blue - RefGen
PIN 6: Green - DRM 0
PIN 7: White brown - METER:A
PIN 8: Brown - METER:B
Figure3-28
Pin definition of inverter’s RJ45 plug
DRM interface
DRM interface is used to connect with the DRM controlling device.