background image

1021 

|

 1022 SMALL AIR COMPRESSOR

03

It is the sole responsibility of the purchaser of Keiser Corporation 
equipment to instruct all individuals, whether they are the 
end-user or supervising personnel, on proper usage of the 
equipment. Keiser Corporation recommends that all users of its 
equipment be informed of the following information before use.

GENERAL SAFETY RULES

1.          Read these instructions. Keep these instructions. 
2.  Heed all warnings. Follow all instructions. 
3.  All repairs and maintenance shall only be performed by 

Keiser-certified technicians. Only use replacement parts 

recommended by Keiser Corporation.

4.  Use the air compressor for its intended purpose as 

described in this manual; for indoor use only.

5.  The air compressor is not a toy. Children shall not play 

with the air compressor. Keep children and pets clear 
from the air compressor at all times, especially while 
in use. Cleaning and user maintenance shall not be 
performed by children.

6.  The air compressor is not to be used by persons 

(including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, 
without instruction and constant supervision.

7.  Do not use attachments or accessories that have not been 

provided or recommended by the manufacturer.

8.  The air compressor is intended for use in training areas 

of organizations where access and control are specifically 

regulated by a person responsible for determining the 
suitability of use and maintenance.

9. 

Operate at 32ºF - 104ºF (0ºC - 40ºC). 

Keep away from 

extreme temperatures and high humidity.

10.  Locate the air compressor in a clean, dry, and well-ventilated 

area. Place the air compressor on a flat, level surface.

11. 

Maintain  adequate  air  flow,  minimum  3-inch  (76  mm) 

obstacle-free perimeter required. 

12.  Use an electrical circuit with the appropriate power rating. 

Do not use extension cords or power cord adapters.

13. 

Do  not  pump  flammable  or  explosive  gases  or  use  in 

an atmosphere that contains such gases. Protect all 
surrounding items from exhaust air. This exhaust air can 
become very hot.

14.  Keep the air compressor away from the workout zone. 

Ensure the power supply is easily accessible. 

15.  Before using the air compressor, perform the Pre-Operation 

Checklist (see page 5). If any damage is found, do not use 

until all repairs have been completed and tested by a Keiser-

certified technician.

16.  Users, agents, and/or anyone directing the use of the 

air compressor shall determine the suitability of the air 
compressor for its intended use, and said parties are 

specifically put on notice that they shall assume all risk 

and liability in connection herewith.

CONVENTIONS USED

This Operator Manual contains the following marks:

DANGER

: Indicates an imminently hazardous situation 

which, if not avoided, will result in death or serious injury.

WARNING

: Indicates a hazardous situation that, if not 

avoided, could result in death or serious injury.

CAUTION

: Indicates a hazardous situation that, if not 

avoided, could result in minor or moderate injury.

HEAVY OBJECT

: Indicates help is required during lifting 

to avoid muscle strain and/or back injury.

SAFETY & SERIAL NUMBER LABELS

Maintain safety and serial number labels. Do not remove 
labels for any reason. They contain important information. 
If unreadable or missing, contact Keiser Corporation for a 
replacement 

(see front cover for contact information)

.

IMPORTANT SAFETY INFORMATION

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │ │ │ │ │ │

888888-88888

│ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │

│ │ │ │ │ │ │

│ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │

│ │ │ │ │ │ │ │

│ │ │ │ │ │ │

00102XXXX

Summary of Contents for 1021

Page 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Page 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Page 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Page 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Page 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Page 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Page 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Page 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Page 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Page 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Page 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Page 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...

Reviews: