background image

1021 

|

 1022 SMALL AIR COMPRESSOR

06

1.  Plug the power cord to the appropriate power supply.

Within  the  first  10  seconds,  the  software  version  will  display  “1.23,” 

followed by the air tank pressure, sequentially.

Example: 85 psig will display as 8-5 [pause]

2.  Slowly purge the air tank until the motor powers ON.
3. 

Allow the air tank to fill (approximately 2–5 minutes).

4.  Check for gauge display to reach between 118–120 psig 

(8.14–8.27 bar). 

TEST PASS:

• 

The software will automatically power OFF the motor when 

the display reads between 118–120 psig (8.14–8.27 bar). 

• 

No air leaks detected. 

TEST FAIL:

• 

The motor does not power OFF when the display reads 

between 118–120 psig (8.14–8.27 bar). 

• 

An air leak detected.

• 

An error buzz sound and error code displays (

“E-r-#”

).

If  the  test  fails,  make  note  of  the  error  code  (if  present) 

and disconnect the power cord from the power supply to 

power  OFF.  Refer  to  the  troubleshooting  section  (page  8) 

for possible corrective action and perform the Test Run 
procedure again. If failure persists, contact your Keiser 
dealer, distributor, or Keiser Customer Support (see front 

cover for contact information).

Air compressor maintenance shall only be performed by 

Keiser-certified technicians.

1. 

Plumbing:

 Connect a 1/4-inch quick-disconnect (QD) from 

the Keiser equipment to any one of the five QD ports. 
A 3/8-inch compression fitting port is also available for 
3/8-inch  air  supply  configurations  (Tools:  Adjustable 
Wrench and 5/8-inch Wrench).

2. 

Power Cord: 

Connect the power cord to the power 

connector. 

3.  Proceed to the Test Run section.

ASSEMBLY

ELECTRIC SHOCK HAZARD

•  Install this product where it will not come into contact with 

water or other liquids.

•  Ensure the power cord is free of damage before connecting 

to the power supply.

•  If the power cord is damaged, or shows signs of excessive 

wear, stop use of the equipment immediately. Do not use 
the equipment until the power cord is replaced. Only use 
power cords provided by Keiser Corporation.

•  This product must be properly grounded. For 120-volt or 

220/240-volt circuits, connect power supply cord grounding 
plug to a matching grounded outlet. Do not use an adapter 

(See diagram below).

•  The plug must be plugged into an outlet that is properly 

installed and grounded in accordance with all local codes 
and ordinances.

• 

Do not modify the power cord provided. Check with a qualified 

electrician or serviceperson if grounding instructions are 
not completely understood.

• 

Failure to follow these instructions can result in death, fire 

or electrical shock.

Grounded 

Plug

120-volt grounded connectors shown. 

220/240-volt grounded connectors will differ in shape.

Grounding 

Pin

Grounded

Outlet

Neutral           Hot

DANGER

ELECTRICAL POWER REQUIREMENTS

Before using the air compressor, check that supply voltage 
agrees with that listed on product serial number label or 

refer  to  the  Equipment  Specifications  section  (page  4).  

Low voltage or an overload circuit can cause the overload 
protection system circuit breaker to trip.

WARNING

EXPLOSION HAZARD

•  Exercise caution when using pressurized air.
• 

Only use hoses and air fittings provided by the manufacturer.

• 

Inspect all hoses and fittings for leaks or wear. If leaks or 

wear are detected, stop use and replace parts immediately. 
Do not use until repairs have been completed and tested 

by a Keiser-certified technician.

•  Never leave pressurized air in the air tanks when storing 

the air compressor or during downtime (maintenance).

•  If the air tank develops a leak, replace the air tank 

immediately. Never repair, weld or make modifications to 

the air tanks or their attachments.

•  Never make adjustments to the factory-set pressures.

TEST RUN

Summary of Contents for 1021

Page 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Page 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Page 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Page 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Page 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Page 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Page 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Page 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Page 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Page 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Page 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Page 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...