Error Code

Description/Symptoms

Probable Cause

Solution

E r 1

Check Valve leak detected.

Check Valve failure. Once 
the compressor builds up 
pressure and shuts off, 
the pressure bleeds down 
rapidly to a low pressure 

(approximately 10 psi). 

Replace Check Valve.

E r 2, E r 8

Motor run-time is too long 

(over one hour); failure to 

reach shut-off pressure 

(approximately 120 psi).

NOTE: Shut-off will occur 
every 5 minutes to purge the 
dryer assembly (display: 

E r 

8

). If after 20 cycles the unit 

fails to reach the shut-off 
pressure, the compressor will 
shut down and not restart 
(display: 

E r 2

).

Air leak within the system.

Check for air leaks in the 
compressor and air line system:
1.  Disconnect all exercise 

machines from the 
compressor.

2.  Reset the compressor 

(disconnect, then reconnect to 

power supply). 

3.  Run the compressor. 

Check the display for building 
pressure and shut-off pressure at 
approximately 120 psi.

If the compressor builds pressure 
and shuts down at shut-off 
pressure, the leak is likely at an 
exercise machine or in the air 
supply line. Check the Air Line 
system for leaks; connect exercise 
machines one at a time to check 
for leaks.

If the compressor fails to shut 
down (exercise machines are 

disconnected), the leak is likely 

in the compressor. Check the 

compressor hoses/fittings for 

leaks.

E r 3, E r 4, E r 5

Purge tank pressure did not 
drop fast enough.

NOTE: The purge tank 
must bleed air through the 
dryer to regenerate. This 
must happen before the 
compressor can restart. If 
this takes too long, these 
error codes will display. 

Blockage in the Dryer 
Module.

Replace the Dryer Module and 
Elbow Connector if corrosion is 
detected.

Mechanical failure of the 
Solenoid Valve

Replace the Solenoid Valve.

If you suspect a problem with the air compressor, check the Display Lens for an error code (“E r” followed by a number). 

An error code will remain on the display until the error self-corrects or when the compressor is reset (disconnect and 

re-connect to power supply) in an attempt to fix the error. The following table lists the 

error code descriptions, probable 

causes, and solutions.

Summary of Contents for 1021

Page 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Page 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Page 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Page 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Page 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Page 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Page 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Page 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Page 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Page 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Page 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Page 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...

Reviews: