background image

1021 

|

 1022 SMALL AIR COMPRESSOR

10

WARRANTY STATEMENT

REGULATORY AND COMPLIANCE NOTICES

For information about Keiser’s product warranty and thereto related information, refer to keiser.com/support/warranty.

COMPLIANCE

This device complies with Industry Canada Licence-Exempt RSS standard(s). Operation is subject to the following two conditions: 
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may 

cause undesired operation of the device.
Le present appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L’exploitation 

est autorisee aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit 

accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement.

REGULATORY NOTICE

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which 
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or 
more of the following measures:

—   Reorient or relocate the receiving antenna.
—   Increase the separation between the equipment and receiver.
—   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—   Consult the dealer or an experienced radio/TV technician for help.

California Proposition 65 Warning: 

This product contains chemicals known in the State of California to cause cancer, 

birth defects, and/or other reproductive harm.

This equipment contains electrical or electronic components that must be recycled properly to comply with 
Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment 

(WEEE). Contact your local dealer for procedures for recycling this equipment.

Summary of Contents for 1021

Page 1: ...stomer Note to Customer Keep Operator Manual for future reference Skill level Professional installation is required by qualified personnel Product failure due to improper installation is not covered u...

Page 2: ...number Serial No in the space provided below Serial No INTRODUCTION RECORD YOUR SERIAL NUMBER GENERAL INFORMATION CONTENTS Registeryourproducttostayinformedofsafetynotifications and for faster more a...

Page 3: ...ilated area Place the air compressor on a flat level surface 11 Maintain adequate air flow minimum 3 inch 76 mm obstacle free perimeter required 12 Useanelectricalcircuitwiththeappropriatepowerrating...

Page 4: ...Rating 61 63 dB Under normal operating conditions distance of 39 37 inches 1 m EQUIPMENT SPECIFICATIONS 26 inches 661 mm 14 inches 356 mm 82 lbs 37 kg 16 inches 407 mm Air Storage Tank The equipment...

Page 5: ...exceed the maximum rated pressure CAUTION HOT SURFACE Air compressor surfaces become hot during operation Do not touch hot surfaces cover during operation as they can cause severe burns Allow the air...

Page 6: ...econnecting to the power supply If the power cord is damaged or shows signs of excessive wear stop use of the equipment immediately Do not use the equipment until the power cord is replaced Only use p...

Page 7: ...epairs have been completed and tested by a Keiser certified technician DAILY OPERATION CARE AND MAINTENANCE CAUTION HOT SURFACE Before cleaning the air compressor 1 Disconnect the power cord from the...

Page 8: ...ct all exercise machines from the compressor 2 Reset the compressor disconnect then reconnect to power supply 3 Run the compressor Check the display for building pressure and shut off pressure at appr...

Page 9: ...not click the Circuit Board is faulty and must be replaced E r 7 Insufficient no pressure build in Air Tanks Major air leak in one of the exercise machines or in the compressor plumbing Check compres...

Page 10: ...armful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmf...

Page 11: ...1021 1022 SMALL AIR COMPRESSOR 11 This page is intentionally left blank...

Page 12: ...the operation or installation of the air compressor after reading this manual contact Keiser Customer Support 105513_D KEISER CORPORATION 2470 S Cherry Ave Fresno CA 93706 1 559 256 8000 service keis...

Reviews: