CALIBRATION PROCEDURE
KEISER M3/M3i & M5/M5i CARDIO EQUIPMENT
2
1X
RPM
WATTS
ODO
ODO
GEAR
1X
RPM
WATTS
ODO
RPM
WATTS
ODO
GEAR
RPM
ODO
GEAR
RPM
ODO
1X
6X
Begin with the Computer off. Then,
push the Resistance Lever to the lowest
position.
Please be sure to read and understand all instructions on page 1 prior to beginning the calibration procedure below.
The M3i Indoor Cycle is featured in the calibration procedure below (M3, M5/M5i similar).
Please note: STEP 3 through STEP 6 must be completed
within 30 seconds
.
Pedal 1 full revolution. The following
“Time Row” value will be displayed:
•
M3i/M5i = “1”
•
M3/M5 = “0:00”
Position the Calibration Tool (Cal Tool):
•
Place the Cal Tool onto the
Flywheel as shown above.
•
Slide the Cal Tool up until the Cal
Tool comes to a hard stop beneath
the Magnet Holder.
Engage the Magnets into the Cal Tool:
•
Turn the Magnet Cover counter-
clocwise until the Magnets stop
against the cutouts in the Cal Tool.
•
Release the Magnet Cover and
allow it to return to its rest position.
•
Remove Cal Tool (it is no longer
needed).
Pedal 1 full revolution. The following
“Time Row” value will be displayed:
•
M3i/M5i = “2”
•
M3/M5 = “0:01”
“CAL’b” will display upon successful completion of the Calibration procedure.
(NOTE: Diagnostic values above the “CAL’b” row will vary).
Allow the computer to
sleep before use.
TROUBLESHOOTING:
If an error symbol “Err#” appears on the display, allow the
computer to enter sleep mode, then begin the calibration procedure again from STEP 1.
If the error persists, note the error number and diagnostic values and contact Keiser
Customer Support at 1 559 256 8000.
CUSTOMER SUPPORT:
If you have any questions regarding this procedure and/or
operation after reading this guide, contact Keiser Customer Support:
1
2
3
4
5
6
Time
Row
M3i/M5i
M3/M5
Time
Row
Magnets
Magnet Cover
(transparent view)
Move the Resistance Lever from stop to
stop 6 times.
IMPORTANT:
Make sure the Resistance
Lever makes the complete travel from stop
to stop all six times. Failure to do so may force
an error.
Cal Tool
cut-outs
Cal Tool
Calibration Successful
M3i/M5i
M3i/M5i
M3/M5
M3/M5
555519_B
© Copyright 2017, Keiser Corporation. All rights reserved.
keiser.com/support
1 559 256 8000
service@keiser.com
Flywheel
Magnet Cover
PLEASE READ ALL INSTRUCTIONS CAREFULLY