5-2
Ratio and Delta
NOTE
When using the Model 2182/2182A with the Model 6220 or 6221 Current Source,
enhanced Delta and Differential Conductance measurements can be performed.
When using the Model 2182A with the Model 6220 Current Source, Pulsed Delta
measurements can be performed.
for details on enhanced Delta, Pulsed Delta, and Differential Con-
ductance.
•
Ratio
— Covers the Ratio calculation, and the effects of Filter, Rel and Ranging.
•
Delta
— Explains how to perform Delta measurements, which are used to cancel the
effects of thermal EMFs in the test leads. Features the use of a Keithley SourceMeter
with the Model 2182 to perform Delta measurements. Includes the effects of Filter on
Delta measurements.
•
SCPI programming
— Covers the SCPI commands used to control Ratio and Delta,
and includes programming examples.
•
Applications
— Provides applications that use Ratio and Delta.
Ratio
Ratio (V1/V2) displays the proportional relationship between the two voltage input channels
(DCV1 and DCV2). Ratio is calculated as follows:
Ratio = V1/V2
Where: V1 is the voltage reading for Channel 1 (DCV1)
V2 is the voltage reading for Channel 2 (DCV2)
Basic procedure
Ratio is selected by pressing the V1/V2 key. The “CH1 / CH2” message appears briefly before
displaying the result of the calculation. The “RA” message is displayed while in Ratio. Ratio is
disabled by selecting a single measurement function (DCV1, DCV2, TEMP1 or TEMP2) or by
selecting Delta.
NOTES
• When Ratio is selected, one of the channel annunciators (CH1 or CH2) will
turn on briefly. This indicates the channel that can be controlled by the manual
range key. After that both the CH1 and CH2 annunciators will turn on. See
“
• If an overflow condition (OVRFLW) occurs, the range that overflowed will
format the display.
• Ratio readings can be stored in the buffer. See
for details on using
the buffer.
• Reading HOLD cannot be used with Ratio. Selecting Ratio (or Delta) disables
HOLD.
• LSYNC (line cycle integration) must be enabled when RATIO is selected.
LSYNC turns on automatically when RATIO is selected and turns off
automatically when exiting RATIO.
Summary of Contents for 2182
Page 1: ...www tek com keithley Model 2182 2182A Nanovoltmeter User s Manual 2182A 900 01 Rev B May 2017...
Page 18: ......
Page 22: ......
Page 23: ...1 Getting Started Getting Started...
Page 41: ...2 VoltageandTemperature Measurements Voltageand Temperature Measurements...
Page 68: ...2 28 Voltage and Temperature Measurements...
Page 69: ...3 Range Digits Rate andFilter Range Digits Rate andFilter...
Page 82: ...3 14 Range Digits Rate and Filter...
Page 83: ...4 Relative mX b and Percent Relative mX b andPercent...
Page 91: ...5 RatioandDelta Ratioand Delta...
Page 117: ...6 Buffer Buffer...
Page 123: ...7 Triggering Triggering...
Page 140: ...7 18 Triggering...
Page 141: ...8 Limits Limits...
Page 149: ...9 SteppingandScanning Steppingand Scanning...
Page 168: ...9 20 Stepping and Scanning...
Page 169: ...10 AnalogOutput Analog Output...
Page 175: ...11 RemoteOperation Remote Operation...
Page 205: ...12 CommonCommands Common Commands...
Page 221: ...13 SCPISignalOriented Measurement Commands SCPISignalOri entedMeasure ment Commands...
Page 225: ...14 SCPIReferenceTables SCPIRefer enceTables...
Page 239: ...15 AdditionalSCPI Commands Additional SCPICom mands...
Page 260: ...15 22 Additional SCPI Commands...
Page 261: ...A Specifications Specifications...
Page 263: ...B Statusand ErrorMessages StatusandError Messages...
Page 268: ...B 6 Status and Error Messages...
Page 269: ...C Measurement Considerations Measurement Consider ations...
Page 278: ...C 10 Measurement Considerations...
Page 279: ...D Model182Emulation Commands Model182 EmulationCom mands...
Page 284: ...D 6 Model 182 Emulation Commands...
Page 285: ...E Example Programs ExamplePro grams...
Page 293: ...F IEEE 488 BusOverview IEEE 488Bus Overview...
Page 307: ...G IEEE 488andSCPI ConformanceInformation IEEE 488and SCPIConform anceInforma tion...
Page 310: ...G 4 IEEE 488 and SCPI Conformance Information...
Page 311: ...H Measurement Queries Measurement Queries...
Page 316: ...H 6 Measurement Queries...
Page 317: ...I Delta PulseDelta and DifferentialConductance Delta Pulse Deltaand Dif ferentialCon ductance...