Section 1: Introduction
Model 4200A-SCS Parameter Analyzer Reference Manual
1-4
4200A-901-01 Rev. C / February 2017
Software features
When you start one of the Clarius
+
applications for the first time, you must agree to the license
agreement before continuing. If you do not respond with "Yes", your system will not function until you
reinstall the software.
You can use the following applications to operate and maintain the 4200A-SCS.
•
Clarius: This is the main 4200A-SCS parameter analysis application. You use Clarius to organize
tests into individual projects. You then use Clarius to manage, execute, and review test results
from the projects.
•
Keithley Configuration Utility (KCon): KCon allows you to configure external GPIB instruments,
switch matrices, and analytical probers connected to the 4200A-SCS. KCon also provides basic
diagnostic and troubleshooting functions.
•
Keithley User Library Tool (KULT): KULT allows you to create algorithms (user modules) in the C
programming language and to then integrate these modules into Clarius. The modules can
control internal 4200A-SCS instrumentation and external instrumentation. You also use KULT to
create and manage libraries of user modules. Requires the optional 4200-COMPILER.
•
Keithley External Control Interface (KXCI): KXCI allows you to use an external computer to
remotely control 4200A-SCS SMUs over the GPIB bus or ethernet.
•
Keithley Pulse Application (KPulse): A non-programming alternative to configure and control
installed 4225-PMU or 4220-PGU pulse units. You can use it for quick tests that require minimal
interaction with other 4200A-SCS test resources.
Embedded computer policy
If you install software that is not part of the standard application software for the 4200A-SCS, the
non-standard software may be removed if the instrument is sent in for service. Back up the
applications and any data related to them before sending the instrument in for service.
Do not reinstall or upgrade the Microsoft
®
Windows
®
operating system (OS) on any 4200A-SCS. This
action should only be performed at an authorized Keithley Instruments service facility. Violation of
this precaution will void the 4200A-SCS warranty and may render the 4200A-SCS unusable. Any
attempt to reinstall or upgrade the operating system (other than a Windows service pack update) will
require a return-to-factory repair and will be treated as an out-of-warranty service, including time and
material charges.
Although you must not attempt to reinstall or upgrade the operating system, you can restore the hard
drive image (complete with the operating system) using the Acronis True Image OEM software tool,
described in
System-level backup and restore software